Permanent pacemaker implantation technique: part II
The DOI matches its Crossref record.
Abstract
Background: Currently there is no agreement on the optimal time to treatment of breast cancer; however, given the considerable emphasis on early detection, one would expect a similar emphasis on early treatment. The purpose of our study was to assess the time interval to surgery from initiation of diagnosis among Quebec women with breast cancer and to examine the influence on waiting time of age, pattern of care and cancer stage. Methods: Records of physician fee-for-service claims and of hospital admissions were obtained for all Quebec women who underwent an invasive procedure for the diagnosis or treatment of breast cancer between 1992 and 1998. Waiting time was calculated as the number of days between the first diagnostic procedure and surgical treatment. Results: There were 29 606 episodes of breast cancer surgery among 28 100 women: 5922 mastectomies and 23 684 lumpectomies. The absolute number of episodes of breast cancer treated with surgery rose from 3626 in 1992 to 5162 in 1998. The overall median waiting time was 34 days (interquartile range [IQR] 19–62); 13.5% of the women waited longer than 90 days. The median waiting time rose from 29 days (IQR 15–54) in 1992 to 42 days (IQR 24–72) in 1998, representing a relative increase of 37% (95% confidence interval [CI] 32%–43%) after adjusting for age and cancer stage. The median waiting time increased with the number of diagnostic procedures, from 24 days (IQR 14–42) with 1 procedure to 48 days (IQR 27–84) with 3 procedures to 72 days (IQR 43–121) with 4 procedures, representing adjusted relative increases of 97% (95% CI 91%–103%) and 194% (95% CI 181%–208%), respectively. The proportion of women receiving 3 or more diagnostic procedures before surgery increased steadily over the study period, from 19.2% in 1992 to 33.0% in 1998. The median waiting time was shorter with more advanced stages of cancer: 53 days (IQR 30–86) for carcinoma in situ, 35 (IQR 20–62) for localized disease, 28 (IQR 16–49) for regional disease and 24 (IQR 11–52) for disseminated disease. Interpretation: Waiting time between initial diagnosis and first surgery for breast cancer has increased substantially in Quebec between 1992 and 1998. Possible explanations include increased demand, decreased resources and changes in patterns of care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Development of Implantable Medical Devices: From an Engineering Perspective
Joung, Y.-H. (2013) · International Neurourology Journal · doi:10.5213/inj.2013.17.3.98 · Cited by 367
Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation
Chang, J. D., Manning, W. J., Ebrille, E., & Zimetbaum, P. J. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.055 · Cited by 238
Cardiac Implantable Electronic Device Lead-Induced Tricuspid Regurgitation
Addetia, K., Harb, S. C., Hahn, R. T., Kapadia, S., & Lang, R. M. (2019) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.09.028 · Cited by 190
Tricuspid Regurgitation and Mortality in Patients With Transvenous Permanent Pacemaker Leads
Delling, F. N., Hassan, Z. K., Piatkowski, G., Tsao, C. W., Rajabali, A., Markson, L. J., Zimetbaum, P. J., Manning, W. J., Chang, J. D., & Mukamal, K. J. (2016) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.12.038 · Cited by 159
Kristiansen, H. M., Hovstad, T., Vollan, G., & Faerestrand, S. (2012) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30458-2 · Cited by 5
“RV-HS lead placement was defined positioning in the inferior part of the RVOT in AP fluoroscopy view with a posterior lead tip orientation in fluoroscopic LAO view [17] (Figure 2).”
MethodInfluential
Metadata
- Authors
- Rajappan, K.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2009-01-28
- Volume
- 95
- Issue
- 4
- Pages
- 334-342
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2123591592
- Cited by
- 72
- References
- 0
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.