Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 173

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode

Open access
Alkadhi, Hatem, Stolzmann, Paul, Desbiolles, Lotus, Baumueller, Stephan, Goetti, Robert, Plass, Andre, Scheffel, Hans, Feuchtner, Gudrun, Falk, Volkmar, Marincek, Borut, Leschka, Sebastian · 2010 · Heart

Abstract

Objective: To compare the diagnostic accuracy and radiation doses of two low-dose protocols for coronary artery imaging with second-generation, dual-source CT in comparison with catheter angiography (CA). Design, setting and patients: Prospective, single-centre study conducted in a referral centre enrolling 100 patients with low-to-intermediate risk and suspicion of coronary artery disease. All patients underwent contrast-enhanced, 128-slice, dual-source CT coronary angiography and CA. Patients were randomly assigned to two different low-dose CT protocols (each 100 kV/320 mA): in group A (n=50), CT was performed using the prospectively electrocardiography (ECG)-gated step-and-shoot (SAS) mode; in group B (n=50), CT was performed using the prospectively ECG-gated high-pitch mode (pitch 3.4). The image quality and presence or absence of significant coronary stenosis in all coronary segments were evaluated by two blinded and independent observers. CA served as the standard of reference. Results: Sixty-one significant stenoses were found in group A, and 69 in group B. There was no significant difference in age (group A, 62±8yrs; group B, 63±8yrs; p=0.72), body mass index (group A, 26.4±3.1kg/m2; group B, 25.9±2.8kg/m2; p=0.41) and heart rate (HR) (group A, 58±8bpm; group B, 56±10bpm; p=0.66) between the groups. Diagnostic image quality was obtained in 98.6% (651/660) of segments in group A and in 98.9% (642/649) in group B, with no significant differences between groups. Sensitivity, specificity and positive and negative predictive values were 94%, 91%, 85% and 97% per-patient in group A, and 93%, 94%, 89% and 97% per-patient in group B (no significant differences). The effective radiation dose in group B (0.9±0.1 mSv) was significantly (p<0.01) lower than that in group A (1.4±0.4 mSv). Conclusions: Both the high-pitch and the SAS mode for low-dose CT coronary angiography provide high accuracy for the assessment of significant coronary stenoses, while the high-pitch mode further significantly lowers the radiation dose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.2009.189100

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 173

Metadata

Authors
Alkadhi, H., Stolzmann, P., Desbiolles, L., Baumueller, S., Goetti, R., Plass, A., Scheffel, H., Feuchtner, G., Falk, V., Marincek, B., & Leschka, S.
Venue
Heart
Publisher
BMJ
Published
2010-06
Volume
96
Issue
12
Pages
933-938
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2169740625
Cited by
173
References
1
FWCI
22.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode. https://app.cochat.ai/papers/10.1136/hrt.2009.189100
The paper
Alkadhi, H., Stolzmann, P., Desbiolles, L., Baumueller, S., Goetti, R., Plass, A., Scheffel, H., Feuchtner, G., Falk, V., Marincek, B., & Leschka, S. (2010). Low-dose, 128-slice, dual-source CT coronary angiography: accuracy and radiation dose of the high-pitch and the step-and-shoot mode. Heart. https://doi.org/10.1136/hrt.2009.189100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.