The DOI matches its Crossref record.
Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation.
Open accessAbstract
Twenty two patients (four men, 18 women, mean age 56 years, range 21 to 88 years) with a history of rheumatic mitral stenosis were studied by cross sectional echocardiography before and after balloon dilatation of the mitral valve. The appearance of the mitral valve on the pre-dilatation echocardiogram was scored for leaflet mobility, leaflet thickening, subvalvar thickening, and calcification. Mitral valve area, left atrial volume, transmitral pressure difference, pulmonary artery pressure, cardiac output, cardiac rhythm, New York Heart Association functional class, age, and sex were also studied. Because there was some increase in valve area in almost all patients the results were classified as optimal or suboptimal (final valve area less than 1.0 cm2, final left atrial pressure greater than 10 mm Hg, or final valve area less than 25% greater than the initial area). The best multiple logistic regression fit was found with the total echocardiographic score alone. A high score (advanced leaflet deformity) was associated with a suboptimal outcome while a low score (a mobile valve with limited thickening) was associated with an optimal outcome. No other haemodynamic or clinical variables emerged as predictors of outcome in this analysis. Examination of pre-dilatation and post-dilatation echocardiograms showed that balloon dilatation reliably resulted in cleavage of the commissural plane and thus an increase in valve area.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Vahanian, A., Beyersdorf, F., Praz, F., Milojevic, M., Baldus, S., Bauersachs, J., Capodanno, D., Conradi, L., De Bonis, M., De Paulis, R., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehab395 · Cited by 5,685
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
Guidelines on the management of valvular heart disease (version 2012)
Authors/Task Force Members, Vahanian, A., Alfieri, O., Andreotti, F., Antunes, M. J., Barón-Esquivias, G., Baumgartner, H., Borger, M. A., Carrel, T. P., De Bonis, M., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs109 · Cited by 3,559
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000029 · Cited by 2,566
Metadata
- Authors
- Wilkins, G. T., Weyman, A. E., Abascal, V. M., Block, P. C., & Palacios, I. F.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1988-10-01
- Volume
- 60
- Issue
- 4
- Pages
- 299-308
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W2100924809
- Cited by
- 1,192
- References
- 0
- FWCI
- 12.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. https://app.cochat.ai/papers/10.1136/hrt.60.4.299
- The paper
- Wilkins, G. T., Weyman, A. E., Abascal, V. M., Block, P. C., & Palacios, I. F. (1988). Percutaneous balloon dilatation of the mitral valve: an analysis of echocardiographic variables related to outcome and the mechanism of dilatation. Heart. https://doi.org/10.1136/hrt.60.4.299
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.