The DOI matches its Crossref record.
What is meant by a "controlled" ventricular rate in atrial fibrillation?
Open accessAbstract
Reduction of a rapid ventricular rate in atrial fibrillation results in a longer diastolic filling period and a higher left ventricular stroke volume but this is offset by reduced contractility and fewer beats per minute; the net effect on cardiac output is uncertain. Sequences of stroke distances were measured by Doppler ultrasound in 60 resting patients with atrial fibrillation to determine the relation between ventricular rate and linear cardiac output. The slope of the cardiac output/ventricular rate relation was positive in all 20 patients with a ventricular rate less than 90 beats per minute and negative in 16 (40%) of 40 patients with a ventricular rate greater than 90 beats per minute. In atrial fibrillation the ventricular rate can be regarded as "controlled" when the cardiac output/ventricular rate slope is positive and "uncontrolled" when the slope is negative--that is when reduction of ventricular rate would lead to increased cardiac output. As so defined, ventricular rate at rest was controlled in every patient when the ventricular rate was less than 90, controlled in 44 (73%) patients when the ventricular rate was 90-140 beats per minute, and uncontrolled in every case when it was greater than 140 beats per minute. Achieving a target ventricular rate of 90 beats per minute in patients with atrial fibrillation at rest would result in control with the least compromise of cardiac output.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: executive summary
Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., Lévy, S., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01587-x · Cited by 1,348
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.009 · Cited by 1,158
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.013 · Cited by 924
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Kay, G. N., Le Huezey, J.-Y., Lowe, J. E., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214876d · Cited by 859
Tsutsui, H., Isobe, M., Ito, H., Ito, H., Okumura, K., Ono, M., Kitakaze, M., Kinugawa, K., Kihara, Y., Goto, Y., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0342 · Cited by 704
Writing Committee Members, Fuster, V., Ryden, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., et al. (2006) · Europace · doi:10.1093/europace/eul097 · Cited by 667
Committee Members, Fuster, V., Rydén, L. E., Asinger, R. W., Cannom, D. S., Crijns, H. J., Frye, R. L., Halperin, J. L., Kay, G. N., Klein, W. W., et al. (2001) · Circulation · doi:10.1161/circ.104.17.2118 · Cited by 604
(2001) · European Heart Journal · doi:10.1053/euhj.2001.2983 · Cited by 494
ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.018 · Cited by 467
Guidelines for Pharmacotherapy of Atrial Fibrillation (JCS 2013): – Digest Version –
JCS Joint Working Group (2014) · Circulation Journal · doi:10.1253/circj.cj-66-0092 · Cited by 427
Farshi, R., Kistner, D., Sarma, J. S. M., Longmate, J. A., & Singh, B. N. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00561-0 · Cited by 363
Atrial fibrillation: current knowledge and recommendations for management*1
LEVY, S. (1998) · European Heart Journal · doi:10.1053/euhj.1998.1050 · Cited by 323
Pharmacological rate control of atrial fibrillation
Tamariz, L. J., & Bass, E. B. (2004) · Cardiology Clinics · doi:10.1016/s0733-8651(03)00111-5 · Cited by 53
Metadata
- Authors
- Rawles, J. M.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1990-03-01
- Volume
- 63
- Issue
- 3
- Pages
- 157-161
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W2054678865
- Cited by
- 164
- References
- 0
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.