Sustained cardiac diastolic changes elicited by ultrafiltration in patients with moderate congestive heart failure: pathophysiological correlates.
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To investigate the pathophysiological (cardiac function and physical performance) significance of clinically silent interstitial lung water accumulation in patients with moderate heart failure; to use isolated ultrafiltration as a means of extravascular fluid reabsorption. DESIGN: Echocardiographic, Doppler, chest x-ray evaluations, and cardiopulmonary tests at baseline, soon after ultrafiltration (veno venous extracorporeal circuit), and four days, one month, and three months later. SETTING: University institute of cardiology. SUBJECTS: 24 patients with heart failure due to idiopathic dilated cardiomyopathy or ischaemic myocardial disease with sinus rhythm and ejection fraction less than 35%. Twelve were randomised to ultrafiltration and 12 were taken as controls. MAIN OUTCOME MEASURES: Left ventricular systolic function (from ultrasonography); Doppler evaluation of mitral, tricuspid, and aortic flow and echo-Doppler determination of cardiac output; radiological score of extravascular lung water; right and left ventricular filling pressures; oxygen consumption at peak exercise and exercise tolerance time in cardiopulmonary tests. RESULTS: Soon after ultrafiltration (1976 (760) ml of fluid removed) the following was observed: a reduction in radiological score of extravascular lung water (from 15(1) to 9(1)) and of right (from 7.1 (2.3) to 2.3 (1.7) mm Hg) and left (from 17.6 (8.8) to 9.5 (6.4) mm Hg) ventricular filling pressures; an increase in oxygen consumption at peak exercise (from 15.8 (3.3) to 17.6 (2) ml/min/kg) and of tolerance time (from 444 (138) to 508 (134) s); a slight decrease in atrial and ventricular dimensions; no changes in the systolic function of the left ventricle; a reduction of the early to late filling ratio in both ventricles (mitral valve from 2 (2) to 1.1 (1.1)); (tricuspid valve from 1.3 (1.3) to 0.69 (0.18)) and an increase in the deceleration time of mitral and tricuspid flow, reflecting a redistribution of filling to late diastole. Variations in the ventricular filling pattern, lung water content, and functional performance persisted for three months in all cases. None of these changes was detected in the control group. CONCLUSIONS: Reduction of interstitial lung water was probably the mechanism whereby ultrafiltration modified the pattern of filling of the two ventricles and improved functional performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
2013 ACCF/AHA Guideline for the Management of Heart Failure
Yancy, C. W., Jessup, M., Bozkurt, B., Butler, J., Casey, D. E., Drazner, M. H., Fonarow, G. C., Geraci, S. A., Horwich, T., Januzzi, J. L., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.05.019 · Cited by 12,536
ACC/AHA 2005 Guideline Update for the Diagnosis and Management of Chronic Heart Failure in the Adult
Hunt, S. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.022 · Cited by 4,154
2005 WRITING COMMITTEE MEMBERS, Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.192065 · Cited by 3,720
WRITING COMMITTEE MEMBERS, Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.167586 · Cited by 2,251
Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., Michl, K., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.11.013 · Cited by 1,374
Determinants and prognostic value of left atrial volume in patients with dilated cardiomyopathy
Rossi, A., Cicoira, M., Zanolla, L., Sandrini, R., Golia, G., Zardini, P., & Enriquez-Sarano, M. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02305-7 · Cited by 354
Determinants of Pulmonary Hypertension in Left Ventricular Dysfunction
Enriquez-Sarano, M., Rossi, A., Seward, J. B., Bailey, K. R., & Tajik, A. J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00436-6 · Cited by 276
Marenzi, G., Lauri, G., Grazi, M., Assanelli, E., Campodonico, J., & Agostoni, P. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01479-6 · Cited by 255
Self-citationPeripherally inserted veno-venous ultrafiltration for rapid treatment of volume overloaded patients
Jaski, B. E., Ha, J., Denys, B. G., Lamba, S., Trupp, R. J., & Abraham, W. T. (2003) · Journal of Cardiac Failure · doi:10.1054/jcaf.2003.28 · Cited by 170
Extracorporeal Ultrafiltration for Fluid Overload in Heart Failure
Costanzo, M. R., Ronco, C., Abraham, W. T., Agostoni, P., Barasch, J., Fonarow, G. C., Gottlieb, S. S., Jaski, B. E., Kazory, A., Levin, A. P., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.528 · Cited by 125
“The device- and therapy-related adverse events observed in previous trials should undergo careful re-evaluation to determine which were preventable or related to operator experience versus those that were inherent to how therapy was delivered or was unpredictable (32,46,47,52).”
BackgroundSelf-citation
Metadata
- Authors
- Pepi, M., Marenzi, G. C., Agostoni, P. G., Doria, E., Barbier, P., Muratori, M., Celeste, F., & Guazzi, M. D.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1993-08-01
- Volume
- 70
- Issue
- 2
- Pages
- 135-140
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W2157658154
- Cited by
- 82
- References
- 0
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.