Errors in manual measurement of QT intervals.

Open access
Murray, A., McLaughlin, N. B., Bourke, J. P., Doig, J. C., Furniss, S. S., Campbell, R. W. · 1994 · Heart
Cited by 171

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To quantify the errors associated with manual measurement of QT intervals and to determine the source of the errors. DESIGN: A randomised study of QT measurement by four cardiologists of electrocardiograms plotted on paper in presentations with different noise levels, paper speeds, amplifier gains, and with and without a second QRST complex to indicate the RR interval. SUBJECTS: Four electrocardiograph leads (I, aVR, V1, V5) recorded in eight healthy people relaxing in a semirecumbent position. MAIN OUTCOME MEASURES: Manual measurement of QT interval in 512 electrocardiograms (eight subjects x four leads x eight presentations x two repeats) by each of four cardiologists. RESULTS: QT intervals measured were significantly longer with greater amplifier gain: by 8 ms for a doubling of gain (p < 0.005), equivalent to a doubling of T wave height. QT intervals measured were significantly longer at slower paper speeds: by 11 ms when paper speed was reduced from 100 to 50 mm/s (p < 0.001) and by 16 ms when speed was further reduced from 50 to 25 mm/s (p < 0.001). Neither the presence of noise nor the presence of a second QRST complex altered the mean QT measurements. There were consistent differences in the measurements between cardiologists, amounting to a maximum mean difference of 20 ms. CONCLUSIONS: Manual measurement of QT interval is significantly affected by the paper speed used to plot the electrocardiogram and by electrocardiogram gain, and hence also T wave amplitude. Manual QT measurement also differed consistently with different cardiologists.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.71.4.386

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
Murray, A., McLaughlin, N. B., Bourke, J. P., Doig, J. C., Furniss, S. S., & Campbell, R. W.
Venue
Heart
Publisher
BMJ
Published
1994-04-01
Volume
71
Issue
4
Pages
386-390
ISSN
1355-6037 (ISSN-L)
OpenAlex
W2075220917
Cited by
171
References
0
FWCI
5.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Errors in manual measurement of QT intervals. https://app.cochat.ai/papers/10.1136/hrt.71.4.386
The paper
Murray, A., McLaughlin, N. B., Bourke, J. P., Doig, J. C., Furniss, S. S., & Campbell, R. W. (1994). Errors in manual measurement of QT intervals. Heart. https://doi.org/10.1136/hrt.71.4.386

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.