Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its Crossref record.

Intravascular ultrasound imaging of angiographically normal coronary arteries: a prospective study in vivo.

Open access
Ge, J., Erbel, R., Gerber, T., Gorge, G., Koch, L., Haude, M., Meyer, J. · 1994 · Heart

Abstract

Intravascular ultrasound imaging (IVUS) was performed to elucidate the discrepancy between clinical history and angiographic findings and to measure the diameter and area of the lumen of the normal left coronary artery in 55 patients who presented with chest pain but had normal coronary angiograms. The left coronary artery (LCA) was scanned with a 4.8F, 20 MHz mechanically rotated ultrasound catheter at 413 sites. Atherosclerotic lesions were identified at 72 (17%) sites in 25 patients. The mean (SD) (range) plaque area was 5.55 (3.56) mm2 (2-26 mm2) and it occupied 28.8 (9.6)% (13-70%) of the coronary cross sectional area. Calcification was detected at 24 (33%) atherosclerotic sites in nine patients. The correlation coefficients for the lumen dimensions measured at normal sites by IVUS and by angiography were r = 0.93 (SEE = 0.43) mm for lumen diameter and r = 0.89 (SEE = 4.27) mm2 for lumen area (both p < 0.001). 16 of the 30 patients in whom no atherosclerotic plaques were detected in the LCA lumen by IVUS had no risk factors of coronary artery disease. The cross sectional area of 90 consecutive images of left main coronary artery (LMCA), proximal left anterior descending coronary artery (proximal LAD), and mid LAD was measured in these 16 subjects. The mean (SEM) areas at end diastole were LMCA 17.33 (7.98) mm2; proximal LAD 13.56 (5.85) mm2; mid LAD 9.75 (4.67) mm2. During the cardiac cycle the cross sectional area changed by 10.2 (4.0)% in the LMCA, by 8.3 (4.7)% in the proximal LAD, and by 9.8 (4.0)% in the mid LAD. In 11 patients with plagues the change in cross sectional area in plague segments (5.8(3.1)%) was significantly lower than in the segments from patients without plagues (p < 0.001). Lumen area reached a maximum in early diastole rather than in late diastole. IVUS can imagine atherosclerotic lesions that are angiographically silent; it also provides detailed information about plague characteristics. The variation in coronary cross sectional area during the cardiac cycle should not be ignored during quantitative analysis. Maximum dimensions in normal segments are reached in early diastole. Further studies are needed to clarify the clinical significance of atherosclerosis detected by IVUS in patients presenting with chest pain but normal coronary angiography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.71.6.572

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Ge, J., Erbel, R., Gerber, T., Gorge, G., Koch, L., Haude, M., & Meyer, J.
Venue
Heart
Publisher
BMJ
Published
1994-06-01
Volume
71
Issue
6
Pages
572-578
ISSN
1355-6037 (ISSN-L)
OpenAlex
W2046860438
Cited by
158
References
0
FWCI
11.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intravascular ultrasound imaging of angiographically normal coronary arteries: a prospective study in vivo. https://app.cochat.ai/papers/10.1136/hrt.71.6.572
The paper
Ge, J., Erbel, R., Gerber, T., Gorge, G., Koch, L., Haude, M., & Meyer, J. (1994). Intravascular ultrasound imaging of angiographically normal coronary arteries: a prospective study in vivo. Heart. https://doi.org/10.1136/hrt.71.6.572

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.