CoChat

Comparison of Doppler derived haemodynamic variables and simultaneous high fidelity pressure measurements in severe pulmonary hypertension.

Open access
Brecker, S J, Gibbs, J S, Fox, K M, Yacoub, M H, Gibson, D G · 1994 · Heart
Cited by 99

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess relations between right ventricular pressure measured with a high fidelity transducer tipped catheter and the characteristics of tricuspid regurgitation recorded with Doppler echocardiography. DESIGN: A prospective non-randomised study of patients with severe pulmonary hypertension referred for consideration of lung transplantation. SETTING: A tertiary referral centre for cardiac and pulmonary disease, with facilities for invasive and non-invasive investigation, and assessment for heart and heart-lung transplantation. PATIENTS: 10 patients with severe pulmonary hypertension being considered for lung transplantation. ENDPOINTS: Peak right ventricular, pulmonary artery, and right atrial pressures; peak positive and negative right ventricular dP/dt; peak Doppler right ventricular-right atrial pressure drop; Doppler derived peak positive and negative right ventricular dP/dt; and time intervals of Q to peak right ventricular pressure and to peak positive and negative right ventricular dP/dt. RESULTS: The mean (SD) pulmonary artery systolic pressure was 109 (29) mm Hg. The peak Doppler right ventricular-right atrial pressure drop underestimated peak right ventricular pressure by 38 (21) mm Hg, and by 21 (18) mm Hg when the Doppler value was added to the measured right atrial pressure (P values < 0.05). This discrepancy was greater for higher pulmonary artery pressures. The timing of peak right ventricular pressure differed, with the Doppler value consistently shorter (mean difference 16 ms, P < 0.05). Values of peak positive and negative right ventricular dP/dt and the time intervals Q-peak positive right ventricular dP/dt and pulmonary closure to the end of the pressure pulse differed between the two techniques in individual patients, but not in a consistent or predictable way. CONCLUSIONS: Doppler echocardiography significantly underestimates the peak right ventricular pressure and the time interval to peak right ventricular pressure in pulmonary hypertension, particularly when severe. These differences may be related to orifice geometry. Digitisation of Doppler records of tricuspid regurgitation provides useful semiquantitative estimates of absolute values and timing of peak positive and negative right ventricular dP/dt. Clinically significant differences may exist, however, and must be considered in individual patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.72.4.384

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 99

Metadata

Authors
Brecker, S. J., Gibbs, J. S., Fox, K. M., Yacoub, M. H., & Gibson, D. G.
Venue
Heart
Publisher
BMJ
Published
1994-10-01
Volume
72
Issue
4
Pages
384-389
ISSN
1355-6037 (ISSN-L)
OpenAlex
W1987769817
Cited by
99
References
1
FWCI
2.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Doppler derived haemodynamic variables and simultaneous high fidelity pressure measurements in severe pulmonary hypertension. https://app.cochat.ai/papers/10.1136/hrt.72.4.384
The paper
Brecker, S. J., Gibbs, J. S., Fox, K. M., Yacoub, M. H., & Gibson, D. G. (1994). Comparison of Doppler derived haemodynamic variables and simultaneous high fidelity pressure measurements in severe pulmonary hypertension. Heart. https://doi.org/10.1136/hrt.72.4.384

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.