Comparison of Doppler derived haemodynamic variables and simultaneous high fidelity pressure measurements in severe pulmonary hypertension.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess relations between right ventricular pressure measured with a high fidelity transducer tipped catheter and the characteristics of tricuspid regurgitation recorded with Doppler echocardiography. DESIGN: A prospective non-randomised study of patients with severe pulmonary hypertension referred for consideration of lung transplantation. SETTING: A tertiary referral centre for cardiac and pulmonary disease, with facilities for invasive and non-invasive investigation, and assessment for heart and heart-lung transplantation. PATIENTS: 10 patients with severe pulmonary hypertension being considered for lung transplantation. ENDPOINTS: Peak right ventricular, pulmonary artery, and right atrial pressures; peak positive and negative right ventricular dP/dt; peak Doppler right ventricular-right atrial pressure drop; Doppler derived peak positive and negative right ventricular dP/dt; and time intervals of Q to peak right ventricular pressure and to peak positive and negative right ventricular dP/dt. RESULTS: The mean (SD) pulmonary artery systolic pressure was 109 (29) mm Hg. The peak Doppler right ventricular-right atrial pressure drop underestimated peak right ventricular pressure by 38 (21) mm Hg, and by 21 (18) mm Hg when the Doppler value was added to the measured right atrial pressure (P values < 0.05). This discrepancy was greater for higher pulmonary artery pressures. The timing of peak right ventricular pressure differed, with the Doppler value consistently shorter (mean difference 16 ms, P < 0.05). Values of peak positive and negative right ventricular dP/dt and the time intervals Q-peak positive right ventricular dP/dt and pulmonary closure to the end of the pressure pulse differed between the two techniques in individual patients, but not in a consistent or predictable way. CONCLUSIONS: Doppler echocardiography significantly underestimates the peak right ventricular pressure and the time interval to peak right ventricular pressure in pulmonary hypertension, particularly when severe. These differences may be related to orifice geometry. Digitisation of Doppler records of tricuspid regurgitation provides useful semiquantitative estimates of absolute values and timing of peak positive and negative right ventricular dP/dt. Clinically significant differences may exist, however, and must be considered in individual patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Diagnosis and Assessment of Pulmonary Arterial Hypertension
Badesch, D. B., Champion, H. C., Gomez Sanchez, M. A., Hoeper, M. M., Loyd, J. E., Manes, A., McGoon, M., Naeije, R., Olschewski, H., Oudiz, R. J., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.011 · Cited by 1,138
Screening, Early Detection, and Diagnosis of Pulmonary Arterial Hypertension
McGoon, M., Gutterman, D., Steen, V., Barst, R., McCrory, D. C., Fortin, T. A., & Loyd, J. E. (2004) · Chest · doi:10.1378/chest.126.1_suppl.14s · Cited by 932
Age-Associated Increases in Pulmonary Artery Systolic Pressure in the General Population
Lam, C. S. P., Borlaug, B. A., Kane, G. C., Enders, F. T., Rodeheffer, R. J., & Redfield, M. M. (2009) · Circulation · doi:10.1161/circulationaha.108.838698 · Cited by 444
Mukerjee, D. (2004) · Rheumatology · doi:10.1093/rheumatology/keh067 · Cited by 376
Janda, S., Shahidi, N., Gin, K., & Swiston, J. (2011) · Heart · doi:10.1136/hrt.2010.212084 · Cited by 375
Metadata
- Authors
- Brecker, S. J., Gibbs, J. S., Fox, K. M., Yacoub, M. H., & Gibson, D. G.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1994-10-01
- Volume
- 72
- Issue
- 4
- Pages
- 384-389
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W1987769817
- Cited by
- 99
- References
- 1
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Doppler derived haemodynamic variables and simultaneous high fidelity pressure measurements in severe pulmonary hypertension. https://app.cochat.ai/papers/10.1136/hrt.72.4.384
- The paper
- Brecker, S. J., Gibbs, J. S., Fox, K. M., Yacoub, M. H., & Gibson, D. G. (1994). Comparison of Doppler derived haemodynamic variables and simultaneous high fidelity pressure measurements in severe pulmonary hypertension. Heart. https://doi.org/10.1136/hrt.72.4.384
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.