Infections after cardioverter-defibrillator implantation: observations in 335 patients over 10 years.
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine the incidence of infection after implantation of a cardioverter-defibrillator and the management of this complication. SUBJECTS: 335 consecutive patients who had a cardioverter-defibrillator implanted between January 1984 and December 1993. MAIN OUTCOME MEASURES: Incidence of infection within the first month after implantation (early infection) and after the first month (late infection). RESULTS: Infections associated with cardioverter-defibrillator devices occurred in 13 patients (3.9%) during a mean follow up of 22 (11) months. All patients had general signs of inflammation, fever (> 37.5 degrees C), and leucocytosis (> 10,000/ml) with or without purulent drainage. Five patients (38%) had infections during the first implantation, whereas eight patients (62%) had infections after replacement of the pulse generator. Early infection was observed in four patients (31%) and late infection in nine (69%). Incidence of infection was higher in patients who underwent epicardial cardioverter-defibrillator implantation (12/207 patients, 5.8%) than in those who received nonthoracotomy lead systems (1/125 patients, 0.8%) (P < 0.05). Infections were caused by staphyloccocus in 10 patients, pseudomonas in two patients, and streptococcus in one patient. The whole device had to be removed in all patients. During a mean follow up of 39 (29) months seven patients died: six of congestive heart failure and one of myocardial reinfarction. CONCLUSIONS: Infection, one of the most serious complications after cardioverter-defibrillator implantation, is associated with increased morbidity and mortality. When infection occurs the system must be removed to avoid a fatal outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Candida Infections of Medical Devices
Kojic, E. M., & Darouiche, R. O. (2004) · Clinical Microbiology Reviews · doi:10.1128/cmr.17.2.255-267.2004 · Cited by 1,055
“Transvenously placed ICDs are associated with a significantly lower incidence of infection than are those implanted through thoracotomy (110).”
BackgroundBaddour, L. M., Epstein, A. E., Erickson, C. C., Knight, B. P., Levison, M. E., Lockhart, P. B., Masoudi, F. A., Okum, E. J., Wilson, W. R., Beerman, L. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.192665 · Cited by 1,030
Diagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices
Chua, J. D., Wilkoff, B. L., Lee, I., Juratli, N., Longworth, D. L., & Gordon, S. M. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-8-200010170-00011 · Cited by 511
Nonvalvular Cardiovascular Device–Related Infections
Baddour, L. M., Bettmann, M. A., Bolger, A. F., Epstein, A. E., Ferrieri, P., Gerber, M. A., Gewitz, M. H., Jacobs, A. K., Levison, M. E., Newburger, J. W., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093201.57771.47 · Cited by 496
Polyzos, K. A., Konstantelias, A. A., & Falagas, M. E. (2015) · EP Europace · doi:10.1093/europace/euv053 · Cited by 493
Sandoe, J. A. T., Barlow, G., Chambers, J. B., Gammage, M., Guleri, A., Howard, P., Olson, E., Perry, J. D., Prendergast, B. D., Spry, M. J., et al. (2015) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dku383 · Cited by 403
Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999
Cabell, C. H., Heidenreich, P. A., Chu, V. H., Moore, C. M., Stryjewski, M. E., Corey, G. R., & Fowler, V. G. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.06.005 · Cited by 397
Chamis, A. L., Peterson, G. E., Cabell, C. H., Corey, G. R., Sorrentino, R. A., Greenfield, R. A., Ryan, T., Reller, L. B., & Fowler, V. G. (2001) · Circulation · doi:10.1161/hc3401.095097 · Cited by 292
Gould, P. A. (2006) · JAMA · doi:10.1001/jama.295.16.1907 · Cited by 288
Health‐Related Quality‐of‐Life Assessment of Patients with Life‐Threatening Ventricular Arrhythmias
HERBST, J. H., GOODMAN, M., FELDSTEIN, S., & REILLY, J. M. (1999) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1999.tb06816.x · Cited by 53
Metadata
- Authors
- Trappe, H. J., Pfitzner, P., Klein, H., & Wenzlaff, P.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1995-01-01
- Volume
- 73
- Issue
- 1
- Pages
- 20-24
- ISSN
- 1355-6037 (ISSN-L)
- OpenAlex
- W1987416244
- Cited by
- 80
- References
- 0
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.