CoChat

Ventilatory responses to exercise in adults after repair of tetralogy of Fallot.

Open access
Clark, A. L., Gatzoulis, M. A., Redington, A. N. · 1995 · Heart
Cited by 48

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Adult patients with total correction of tetralogy of Fallot may have poor exercise capacity associated with impaired right heart function and in particular pulmonary regurgitation. The ventilatory responses to exercise were studied in a group of such patients to assess relations between ventilation, exercise capacity, and right ventricular function. METHODS: 30 patients (7 female) (aged 27.8 (6.0) years) and 30 (7 female) controls of a similar age range were studied prospectively. All underwent exercise testing with metabolic gas exchange to determine peak oxygen consumption (peak VO2), and (as indices of the ventilatory response) the slope of the relation between both respiratory rate (RR) and ventilation (VE) against carbon dioxide production (VCO2). Patients were studied with pulsed wave Doppler echocardiography to determine pulmonary arterial systolic and diastolic flow characteristics. Patients were defined as having restrictive right ventricular function where diastolic pulmonary forward flow was seen coincident with atrial systole. RESULTS: In the group with tetralogy of Fallot mean (SD) peak VO2 was 35.3 (7.5) ml/kg/min (93.6 (15.3) % of expected for age, weight, height and sex). The RR/VCO2 slope was steeper in the Fallot group (6.8 (2.6) v 9.6 (4.7), P < 0.02). Those with restrictive right ventricles achieved a higher peak VO2 than those without (82.5 (10.1) % v 100.9 (13.8), P < 0.001). In the Fallot group alone, there was an inverse relation between ventilatory response and peak VO2 (RR/VCO2 v peak VO2; r = -0.63, P = 0.003: VE/VCO2 v peak VO2; r = -0.62, P < 0.001). CONCLUSIONS: Many of these patients with repaired tetralogy of Fallot had near normal exercise capacity, but as exercise capacity decreased, the ventilatory response to exercise increased. This was not due to alterations in pulmonary function tests or to the effects of cardiac size causing decreased lung volume. It may be that the increased ventilatory rate at a given level of carbon dioxide production acts as a respiratory pump aiding right ventricular function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.73.5.445

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 48

Metadata

Authors
Clark, A. L., Gatzoulis, M. A., & Redington, A. N.
Venue
Heart
Publisher
BMJ
Published
1995-05-01
Volume
73
Issue
5
Pages
445-449
ISSN
1355-6037 (ISSN-L)
OpenAlex
W2110710788
Cited by
48
References
2
FWCI
0.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.