Shuttle walking test: a new approach for evaluating patients with pacemakers.
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To validate an incremental field walking test, the shuttle walking test, as a means of assessing pacing modes and to aid programming of rate responsive pacemakers. DESIGN: Three separate groups of patients were recruited. Reproducibility (n = 10) of the shuttle walking test was assessed by performing three consecutive tests. Comparison of the shuttle walking test with a 10 min walk was assessed in 20 patients. In the third group (n = 10) patients with rate responsive pacemakers were programmed to either VVI fixed rate 70 beats/min or VVIR with the optimal rate response to show the discriminative value of the test. SETTING: Pacing clinic in a regional cardiothoracic centre. PATIENTS: 30 patients with chronotropic competence and dual chamber pacemakers with varying functional capacity and 10 patients with rate responsive pacemakers. INTERVENTIONS: Continuous haemodynamic monitoring was obtained using an ambulatory nuclear monitor, the Capintec VEST. Two exercise tests either shuttle walking test or 10 min corridor walk. The shuttle walk is an incremental walking test conducted on a 10 m course where the walking speed is dictated by bleeps on an audio cassette. RESULTS: Reproducibility was demonstrated over three consecutive tests with mean (1 SD) exercise times of 7.6 (1.7) min, 7.7 (1.6), and 7.7 (1.7) min. During the shuttle walk the test patients walked for a mean of 8.3 (1.2) min producing peak relative cardiac outputs of 78 (21) end diastolic volume/min compared with 64.9 (17) end diastolic volume/min for the 10 min walk (P < 0.001); peak heart rates were 118 and 104 beats/min (P < 0.03) respectively. In the third group relative peak cardiac output was significantly greater in VVIR (70 (24) v VVI 52 (15) end diastolic volume/min) (P < 0.009) as were exercise times (VVIR 8.8 (1.3) min v VVI 8.1 (1.3) min) (P < 0.003). CONCLUSIONS: The shuttle walk is an easy test to administer, requiring little equipment. It produces a symptom limited maximal performance and will be a useful aid to pacemaker programming as it is reproducible and able to show differences in exercise capacity between pacing modes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Solway, S., Brooks, D., Lacasse, Y., & Thomas, S. (2001) · Chest · doi:10.1378/chest.119.1.256 · Cited by 1,063
Submaximal Exercise Testing: Clinical Application and Interpretation
Noonan, V., & Dean, E. (2000) · Physical Therapy · doi:10.1093/ptj/80.8.782 · Cited by 637
Jolly, K., Taylor, R., Lip, G., Greenfield, S., Raftery, J., Mant, J., Lane, D., Jones, M., Lee, K., & Stevens, A. (2007) · Health Technology Assessment · doi:10.3310/hta11350 · Cited by 216
Pratt, R. K., Fairbank, J. C. T., & Virr, A. (2002) · Spine · doi:10.1097/00007632-200201010-00020 · Cited by 204
“The functional status of the patients was assessed using the Shuttle Walking Test (SWT), developed originally to assess exercise tolerance in patients with chronic obstructive airway disease(27) and those with cardiac disorders.(22,24) A tape of the SWT is available from Pulmonary Rehab Coordinator, Respiratory Medici…”
MethodDretzke, J., Toff, W. D., Lip, G. Y., Raftery, J., Fry-Smith, A., & Taylor, R. S. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003710.pub2 · Cited by 89
Metadata
- Authors
- Payne, G. E., & Skehan, J. D.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1996-04
- Volume
- 75
- Issue
- 4
- Pages
- 414-418
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W1982870051
- Cited by
- 50
- References
- 0
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shuttle walking test: a new approach for evaluating patients with pacemakers. https://app.cochat.ai/papers/10.1136/hrt.75.4.414
- The paper
- Payne, G. E., & Skehan, J. D. (1996). Shuttle walking test: a new approach for evaluating patients with pacemakers. Heart. https://doi.org/10.1136/hrt.75.4.414
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.