The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound.
Open accessAbstract
BACKGROUND: OCT can image plaque microstructure at a level of resolution not previously demonstrated with other imaging techniques because it uses infrared light rather than acoustic waves. OBJECTIVES: To compare optical coherence tomography (OCT) and intravascular ultrasound (IVUS) imaging of in vitro atherosclerotic plaques. METHODS: Segments of abdominal aorta were obtained immediately before postmortem examination. Images of 20 sites from five patients were acquired with OCT (operating at an optical wavelength of 1300 nm which was delivered to the sample through an optical fibre) and a 30 MHz ultrasonic transducer. After imaging, the microstructure of the tissue was assessed by routine histological processing. RESULTS: OCT yielded superior structural information in all plaques examined. The mean (SEM) axial resolution of OCT and IVUS imaging was 16 (1) and 110 (7), respectively, as determined by the point spread function from a mirror. Furthermore, the dynamic range of OCT was 109 dB compared with 43 dB for IVUS imaging. CONCLUSIONS: OCT represents a promising new technology for intracoronary imaging because of its high resolution, broad dynamic range, and ability to be delivered through intravascular catheters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cited by
Hatsukami, T. S., Ross, R., Polissar, N. L., & Yuan, C. (2000) · Circulation · doi:10.1161/01.cir.102.9.959 · Cited by 622
Demonstration of Dispersion-Canceled Quantum-Optical Coherence Tomography
Nasr, M. B., Saleh, B. E. A., Sergienko, A. V., & Teich, M. C. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.083601 · Cited by 337
Moreno, P. R., Lodder, R. A., Purushothaman, K. R., Charash, W. E., O’Connor, W. N., & Muller, J. E. (2002) · Circulation · doi:10.1161/hc0802.104291 · Cited by 296
Metadata
- Authors
- Brezinski, M. E., Tearney, G. J., Weissman, N. J., Boppart, S. A., Bouma, B. E., Hee, M. R., Weyman, A. E., Swanson, E. A., Southern, J. F., & Fujimoto, J. G.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1997-05
- Volume
- 77
- Issue
- 5
- Pages
- 397-403
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2131958512
- Cited by
- 241
- References
- 1
- FWCI
- 11.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound. https://app.cochat.ai/papers/10.1136/hrt.77.5.397
- The paper
- Brezinski, M. E., Tearney, G. J., Weissman, N. J., Boppart, S. A., Bouma, B. E., Hee, M. R., Weyman, A. E., Swanson, E. A., Southern, J. F., & Fujimoto, J. G. (1997). Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound. Heart. https://doi.org/10.1136/hrt.77.5.397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.