Percutaneous balloon mitral commissurotomy during pregnancy.
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate the effectiveness and safety of percutaneous balloon mitral commissurotomy for the treatment of pregnant women with severe mitral stenosis over a period of six years. DESIGN: Analysis of clinical, haemodynamic, and echocardiographic data before and immediately after the procedure, the pregnancy outcome, and the fate of newborn babies. SETTING: Academic cardiovascular centre in Monastir, Tunisia. PATIENTS: 44 pregnant patients who underwent percutaneous transvenous dilatation of the mitral valve between January 1990 and February 1996. Grade 2 mitral regurgitation was present in two patients and densely calcific valves in three (7%). RESULTS: Commissurotomy was successfully achieved in all cases. The total mean (SD) duration of teh procedure was 72 (18) minutes and that of fluoroscopy 16 (7) minutes. Left atrial pressure decreased from 28 (10) to 14 (7) mm Hg, mitral pressure gradient fell from 22 (8) to 5 (3) mm Hg. Cardiac output increased from 4.8 (1.1) to 6.3 (1.2) l/min and Gorlin mitral valve area from 0.96 (0.21) to 2.4 (0.4) cm2 (all P < < 0.001). Cross sectional echocardiographic mitral valve area increased from 1.07 (0.21) to 2.32 (0.36) cm2. There were no maternal or fetal deaths. Complications included a grade 4 mitral regurgitation in one patient that required early valve replacement. All patients delivered at full term, 42 vaginally and two (5%) by caesarean section; 41 babies were normal and three whose mothers had the procedure near term were relatively hypotrophic. At a mean follow up of 28 (12) months (range 2 to 26) all children had normal growth. CONCLUSIONS: During pregnancy, balloon mitral commissurotomy is the treatment of choice of severe pliable mitral stenosis in patients who are refractory to medical treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000923 · Cited by 3,686
2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.536 · Cited by 3,523
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000031 · Cited by 2,905
Nishimura, R. A., Otto, C. M., Bonow, R. O., Carabello, B. A., Erwin, J. P., Guyton, R. A., O’Gara, P. T., Ruiz, C. E., Skubas, N. J., Sorajja, P., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000029 · Cited by 2,566
Otto, C. M., Nishimura, R. A., Bonow, R. O., Carabello, B. A., Erwin, J. P., Gentile, F., Jneid, H., Krieger, E. V., Mack, M., McLeod, C., et al. (2021) · Circulation · doi:10.1161/cir.0000000000000932 · Cited by 2,449
Metadata
- Authors
- Ben Farhat, M., Gamra, H., Betbout, F., Maatouk, F., Jarrar, M., Addad, F., Tiss, M., Hammami, S., Chahbani, I., & Thaalbi, R.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 1997-06
- Volume
- 77
- Issue
- 6
- Pages
- 564-567
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2170610187
- Cited by
- 94
- References
- 0
- FWCI
- 2.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous balloon mitral commissurotomy during pregnancy. https://app.cochat.ai/papers/10.1136/hrt.77.6.564
- The paper
- Ben Farhat, M., Gamra, H., Betbout, F., Maatouk, F., Jarrar, M., Addad, F., Tiss, M., Hammami, S., Chahbani, I., & Thaalbi, R. (1997). Percutaneous balloon mitral commissurotomy during pregnancy. Heart. https://doi.org/10.1136/hrt.77.6.564
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.