Florid psychopathology in patients receiving shocks from implanted cardioverter-defibrillators

Open access
Bourke, John P, Turkington, Douglas, Thomas, Gareth, McComb, Janet M, Tynan, Margaret · 1997 · Heart
Cited by 89

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objectives: To increase awareness of the potential for disabling anxiety and depression in patients receiving shocks from implanted cardioverter-defibrillators (ICDs). Patients and methods: ICDs are implanted in patients at this hospital for control of serious ventricular tachyarrhythmias inadequately controlled by drug treatment, who are unsuitable for map guided antiarrhythmic surgery. All are reviewed regularly at a dedicated ICD clinic and are advised to make contact between visits if they experience shocks. Symptoms of anxiety or depression were not actively sought, nor was a patient support group operating at the time of this data collection. When overt psychopathology was identified, patients were referred to a designated psychiatrist for management. Results: Over a six year period, six (17%) of 35 patients with ICDs developed florid psychiatric problems after experiencing shocks. None had premorbid psychiatric predisposition. Of the six patients suffering severe psychiatric problems, four were men, their age range was 30–63 years, and left ventricular ejection fraction was 18–40%. All shocks were appropriate for clinical arrhythmias and ranged in frequency from two in six months to 111 in 24 hours. All six patients manifested severe anxiety, focused on fear of future shocks. Depression was also evident in three patients and two had become housebound. All responded within weeks to anxiolytic or antidepressant drugs, combined with relaxation and cognitive therapies. Ongoing psychiatric therapy was refused by one patient, and was required for between three and 18 months in the remainder. One patient died and one received a cardiac transplant during the follow up period (median 27.5 months, range 8–43). Conclusions: Because ICD implantation occurs against a complex medical background with inevitable psychological stress, all such patients should be considered at high risk for developing psychopathology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.78.6.581

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Bourke, J. P., Turkington, D., Thomas, G., McComb, J. M., & Tynan, M.
Venue
Heart
Publisher
BMJ
Published
1997-12-01
Volume
78
Issue
6
Pages
581-583
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2155762169
Cited by
89
References
2
FWCI
1.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.