CoChat

Ventriculo-atrial time interval measured on M mode echocardiography: a determining element in diagnosis, treatment, and prognosis of fetal supraventricular tachycardia

Open access
Jaeggi, E, Fouron, J C, Fournier, A, van Doesburg, N, Drblik, S P, Proulx, F · 1998 · Heart
Cited by 95

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: To determine whether M mode echocardiography can differentiate fetal supraventricular tachycardia according to the ventriculo-atrial (VA) time interval, and if the resulting division into short and long VA intervals holds any relation with clinical presentation, management, and fetal outcome. Design: Retrospective case series. Subjects: 23 fetuses with supraventricular tachycardia. Main outcome measures: A systematic review of the M mode echocardiograms (for VA and atrioventricular (AV) interval measurements), clinical profile, and final outcome. Results: 19 fetuses (82.6%) had supraventricular tachycardia of the short VA type (mean (SD) VA/AV ratio 0.34 (0.16); heart rate 231 (29) beats/min). Tachycardia was sustained in six and intermittent in 13. Hydrops was present in three (15.7%). Digoxin, the first drug given in 14, failed to control tachycardia in five. Three of these then received sotalol and converted to sinus rhythm. All fetuses of this group survived. Postnatally, supraventricular tachycardia recurred in three, two having Wolff-Parkinson-White syndrome. Four fetuses (17.4%) had long VA tachycardia (VA/AV ratio 3.89 (0.82); heart rate 226 (10) beats/min). Initial treatment with digoxin was ineffective in all, but sotalol was effective in two. Heart failure caused fetal death in one and premature delivery in one. All three surviving fetuses had recurrences of supraventricular tachycardia after birth: two had the permanent form of junctional reciprocating tachycardia and one had atrial ectopic tachycardia. Conclusions: Careful measurement of ventriculo-atrial intervals on fetal M mode echocardiography can be used to distinguish short from long VA supraventricular tachycardia and may be helpful in optimising management. Digoxin, when indicated, may remain the drug of choice in the short VA type but appears ineffective in the long VA type.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.79.6.582

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Jaeggi, E., Fouron, J. C., Fournier, A., van Doesburg, N., Drblik, S. P., & Proulx, F.
Venue
Heart
Publisher
BMJ
Published
1998-06-01
Volume
79
Issue
6
Pages
582-587
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W1966813048
Cited by
95
References
2
FWCI
1.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.