Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 449

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Understanding and Using DICOM, the Data Interchange Standard for Biomedical Imaging

Open access
Bidgood, W. D., Horii, S. C., Prior, F. W., Van Syckle, D. E. · 1997 · Journal of the American Medical Informatics Association

Abstract

The Digital Imaging and Communications in Medicine (DICOM) Standard specifies a non-proprietary data interchange protocol, digital image format, and file structure for biomedical images and image-related information. The fundamental concepts of the DICOM message protocol, services, and information objects are reviewed as background for a detailed discussion of the functionality of DICOM; the innovations and limitations of the Standard; and the impact of various DICOM features on information system users. DICOM addresses five general application areas: (1) network image management, (2) network image interpretation management, (3) network print management, (4) imaging procedure management, (5) off-line storage media management. DICOM is a complete specification of the elements required to achieve a practical level of automatic interoperability between biomedical imaging computer systems--from application layer to bit-stream encoding. The Standard is being extended and expanded in modular fashion to support new applications and incorporate new technology. An interface to other Information Systems provides for shared management of patient, procedure, and results information related to images. A Conformance Statement template enables a knowledgeable user to determine if interoperability between two implementations is possible. Knowledge of DICOM's benefits and realistic understanding of its limitations enable one to use the Standard effectively as the basis for a long term implementation strategy for image management and communications systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jamia.1997.0040199

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 449

Metadata

Authors
Bidgood, W. D., Horii, S. C., Prior, F. W., & Van Syckle, D. E.
Venue
Journal of the American Medical Informatics Association
Published
1997-05-01
Volume
4
Issue
3
Pages
199-212
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2106366262
Cited by
449
References
1
FWCI
31.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Understanding and Using DICOM, the Data Interchange Standard for Biomedical Imaging. https://app.cochat.ai/papers/10.1136/jamia.1997.0040199
The paper
Bidgood, W. D., Horii, S. C., Prior, F. W., & Van Syckle, D. E. (1997). Understanding and Using DICOM, the Data Interchange Standard for Biomedical Imaging. Journal of the American Medical Informatics Association. https://doi.org/10.1136/jamia.1997.0040199

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.