Contrasting Views of Physicians and Nurses about an Inpatient Computer-based Provider Order-entry System
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Many hospitals are investing in computer-based provider order-entry (POE) systems, and providers' evaluations have proved important for the success of the systems. The authors assessed how physicians and nurses viewed the effects of one modified commercial POE system on time spent patients, resource utilization, errors with orders, and overall quality of care. DESIGN: Survey. MEASUREMENTS: Opinions of 271 POE users on medicine wards of an urban teaching hospital: 96 medical house officers, 49 attending physicians, 19 clinical fellows with heavy inpatient loads, and 107 nurses. RESULTS: Responses were received from 85 percent of the sample. Most physicians and nurses agreed that orders were executed faster under POE. About 30 percent of house officers and attendings or fellows, compared with 56 percent of nurses, reported improvement in overall quality of care with POE. Forty-four percent of house officers and 34 percent of attendings/fellows reported that their time with patients decreased, whereas 56 percent of nurses indicated that their time with patients increased (P < 0.001). Sixty percent of house officers and 41 percent of attendings/fellows indicated that order errors increased, whereas 69 percent of nurses indicated a decrease or no change in errors. Although most nurses reported no change in the frequency of ordering tests and medications with POE, 61 percent of house officers reported an increased frequency. CONCLUSION: Physicians and nurses had markedly different views about effects of a POE system on patient care, highlighting the need to consider both perspectives when assessing the impact of POE. With this POE system, most nurses saw beneficial effects, whereas many physicians saw negative effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Massaro, T. A. (1993) · Academic Medicine · doi:10.1097/00001888-199301000-00003 · Cited by 287
Cited by
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
Computer Physician Order Entry: Benefits, Costs, and Issues
Kuperman, G. J., & Gibson, R. F. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-139-1-200307010-00010 · Cited by 438
Determinants of Success of Inpatient Clinical Information Systems: A Literature Review
van der Meijden, M. J. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1094 · Cited by 363
Improving Recognition of Drug Interactions: Benefits and Barriers to Using Automated Drug Alerts
Glassman, P. A., Simon, B., Belperio, P., & Lanto, A. (2002) · Medical Care · doi:10.1097/00005650-200212000-00004 · Cited by 279
The Technology Acceptance Model: Predicting Nurses' Intention to Use Telemedicine Technology (eICU)
KOWITLAWAKUL, Y. (2011) · CIN: Computers, Informatics, Nursing · doi:10.1097/ncn.0b013e3181f9dd4a · Cited by 272
Metadata
- Authors
- Weiner, M., Gress, T., Thiemann, D. R., Jenckes, M., Reel, S. L., Mandell, S. F., & Bass, E. B.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-05-01
- Volume
- 6
- Issue
- 3
- Pages
- 234-244
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W1490210891
- Cited by
- 112
- References
- 1
- FWCI
- 12.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contrasting Views of Physicians and Nurses about an Inpatient Computer-based Provider Order-entry System. https://app.cochat.ai/papers/10.1136/jamia.1999.0060234
- The paper
- Weiner, M., Gress, T., Thiemann, D. R., Jenckes, M., Reel, S. L., Mandell, S. F., & Bass, E. B. (1999). Contrasting Views of Physicians and Nurses about an Inpatient Computer-based Provider Order-entry System. Journal of the American Medical Informatics Association. https://doi.org/10.1136/jamia.1999.0060234
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.