Comparative Evaluation of Three Continuous Speech Recognition Software Packages in the Generation of Medical Reports
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To compare out-of-box performance of three commercially available continuous speech recognition software packages: IBM ViaVoice 98 with General Medicine Vocabulary; Dragon Systems NaturallySpeaking Medical Suite, version 3.0; and L&H Voice Xpress for Medicine, General Medicine Edition, version 1.2. DESIGN: Twelve physicians completed minimal training with each software package and then dictated a medical progress note and discharge summary drawn from actual records. MEASUREMENTS: Errors in recognition of medical vocabulary, medical abbreviations, and general English vocabulary were compared across packages using a rigorous, standardized approach to scoring. RESULTS: The IBM software was found to have the lowest mean error rate for vocabulary recognition (7.0 to 9.1 percent) followed by the L&H software (13.4 to 15.1 percent) and then Dragon software (14.1 to 15.2 percent). The IBM software was found to perform better than both the Dragon and the L&H software in the recognition of general English vocabulary and medical abbreviations. CONCLUSION: This study is one of a few attempts at a robust evaluation of the performance of continuous speech recognition software. Results of this study suggest that with minimal training, the IBM software outperforms the other products in the domain of general medicine; however, results may vary with domain. Additional training is likely to improve the out-of-box performance of all three products. Although the IBM software was found to have the lowest overall error rate, successive generations of speech recognition software are likely to surpass the accuracy rates found in this investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Use and Interpretation of Quasi-Experimental Studies in Medical Informatics
Harris, A. D., McGregor, J. C., Perencevich, E. N., Furuno, J. P., Zhu, J., Peterson, D. E., & Finkelstein, J. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1749 · Cited by 1,023
A systematic review of speech recognition technology in health care
Johnson, M., Lapkin, S., Long, V., Sanchez, P., Suominen, H., Basilakis, J., & Dawson, L. (2014) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-14-94 · Cited by 141
“Other researchers used SR systems with supplementary accessories for managing text information such as generic templates [22], medical or pathology terminology dictionary [18,20,33,38], Radiology Information System (RIS) [37] and Picture Archiving and Communication System (PACS) [36].”
BackgroundMethodResultInfluentialSpeech recognition for clinical documentation from 1990 to 2018: a systematic review
Blackley, S. V., Huynh, J., Wang, L., Korach, Z., & Zhou, L. (2019) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy179 · Cited by 97
Joseph, J., Moore, Z. E. H., Patton, D., O'Connor, T., & Nugent, L. E. (2020) · Journal of Clinical Nursing · doi:10.1111/jocn.15261 · Cited by 49
Bourguet, M.-L. (2006) · Signal Processing · doi:10.1016/j.sigpro.2006.02.047 · Cited by 30
Metadata
- Authors
- Devine, E. G., Gaehde, S. A., & Curtis, A. C.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-09-01
- Volume
- 7
- Issue
- 5
- Pages
- 462-468
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W1510525348
- Cited by
- 92
- References
- 0
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative Evaluation of Three Continuous Speech Recognition Software Packages in the Generation of Medical Reports. https://app.cochat.ai/papers/10.1136/jamia.2000.0070462
- The paper
- Devine, E. G., Gaehde, S. A., & Curtis, A. C. (2000). Comparative Evaluation of Three Continuous Speech Recognition Software Packages in the Generation of Medical Reports. Journal of the American Medical Informatics Association. https://doi.org/10.1136/jamia.2000.0070462
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.