CoChat

Comparative Evaluation of Three Continuous Speech Recognition Software Packages in the Generation of Medical Reports

Open access
Devine, E. G., Gaehde, S. A., Curtis, A. C. · 2000 · Journal of the American Medical Informatics Association
Cited by 92

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To compare out-of-box performance of three commercially available continuous speech recognition software packages: IBM ViaVoice 98 with General Medicine Vocabulary; Dragon Systems NaturallySpeaking Medical Suite, version 3.0; and L&H Voice Xpress for Medicine, General Medicine Edition, version 1.2. DESIGN: Twelve physicians completed minimal training with each software package and then dictated a medical progress note and discharge summary drawn from actual records. MEASUREMENTS: Errors in recognition of medical vocabulary, medical abbreviations, and general English vocabulary were compared across packages using a rigorous, standardized approach to scoring. RESULTS: The IBM software was found to have the lowest mean error rate for vocabulary recognition (7.0 to 9.1 percent) followed by the L&H software (13.4 to 15.1 percent) and then Dragon software (14.1 to 15.2 percent). The IBM software was found to perform better than both the Dragon and the L&H software in the recognition of general English vocabulary and medical abbreviations. CONCLUSION: This study is one of a few attempts at a robust evaluation of the performance of continuous speech recognition software. Results of this study suggest that with minimal training, the IBM software outperforms the other products in the domain of general medicine; however, results may vary with domain. Additional training is likely to improve the out-of-box performance of all three products. Although the IBM software was found to have the lowest overall error rate, successive generations of speech recognition software are likely to surpass the accuracy rates found in this investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jamia.2000.0070462

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 92

Metadata

Authors
Devine, E. G., Gaehde, S. A., & Curtis, A. C.
Venue
Journal of the American Medical Informatics Association
Published
2000-09-01
Volume
7
Issue
5
Pages
462-468
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W1510525348
Cited by
92
References
0
FWCI
4.16
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative Evaluation of Three Continuous Speech Recognition Software Packages in the Generation of Medical Reports. https://app.cochat.ai/papers/10.1136/jamia.2000.0070462
The paper
Devine, E. G., Gaehde, S. A., & Curtis, A. C. (2000). Comparative Evaluation of Three Continuous Speech Recognition Software Packages in the Generation of Medical Reports. Journal of the American Medical Informatics Association. https://doi.org/10.1136/jamia.2000.0070462

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.