Internal quality control: best practice
The DOI matches its Crossref record.
Abstract
There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
“There are many other practical issues in routine SQC applications and operations, as discussed recently by Kinns et al.53 These authors provide a lot of practical advice that is particularly oriented to NHS laboratories, including guidance for selection of SQC materials, assigning an SQC range, design of an SQC system…”
Vanstapel, F. J. L. A., Orth, M., Streichert, T., Capoluongo, E. D., Oosterhuis, W. P., Çubukçu, H. C., Bernabeu-Andreu, F. A., Thelen, M., Jacobs, L. H. J., Linko, S., et al. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-0045 · Cited by 45
Çubukçu, H. C. (2021) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2021-0199 · Cited by 13
“…a laboratory professional may intend to detect systematic errors higher than 1.5 SD and substantial random errors, in this case, EWMA ( λ =0.2) may be preferred for preserving Ped ≥ 0.9, and may combine with the “ 1 – 3s ” rule which can cover random errors [20] while maintaining Pfr ≤ 0.05.”
MethodInfluentialStatus of internal quality control for thyroid hormones immunoassays from 2011 to 2016 in China
Zhang, S., Wang, W., Zhao, H., He, F., Zhong, K., Yuan, S., & Wang, Z. (2018) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22154 · Cited by 10
Metadata
- Authors
- Kinns, H., Pitkin, S., Housley, D., & Freedman, D. B.
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 2013-09-26
- Volume
- 66
- Issue
- 12
- Pages
- 1027-1032
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- OpenAlex
- W2134827348
- Cited by
- 66
- References
- 0
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.