Sampling variability of percutaneous liver biopsy in primary sclerosing cholangitis.
Open accessThe DOI matches its Crossref record.
Abstract
AIMS--To study sampling variability of percutaneous liver biopsy in primary sclerosing cholangitis (PSC). METHODS--One hundred and twelve biopsy specimens (that is, 56 pairs) from 44 patients with PSC, confirmed by cholangiography, were evaluated blindly. Six different features, qualitative grading of four other features and staging according to Ludwig were assessed. RESULTS--Quantitative sampling variability was confined mainly to just one grade or stage, although 11% (six of 56) of the biopsy specimen pairs differed by more than one stage (7% (one of 15) in pairs > 2 cm in length). Qualitative sampling variabilities were between 18 and 71%. Advanced disease (stages 3 or 4) was missed in 40% (two of five) of the biopsy specimens while cirrhosis was missed in 37%. CONCLUSION--Paired liver biopsy specimens should be taken in clinical studies of PSC using liver histology for evaluation or prognosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sampling Variability of Liver Biopsy in Nonalcoholic Fatty Liver Disease
Ratziu, V., Charlotte, F., Heurtier, A., Gombert, S., Giral, P., Bruckert, E., Grimaldi, A., Capron, F., & Poynard, T. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.03.084 · Cited by 2,106
Primary sclerosing cholangitis – a comprehensive review
Karlsen, T. H., Folseraas, T., Thorburn, D., & Vesterhus, M. (2017) · Journal of Hepatology · doi:10.1016/j.jhep.2017.07.022 · Cited by 868
“Histology may be subject to considerable sampling variability in PSC (169), although the clinical importance of the sampling error is disputed by some (170).”
BackgroundQuantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Evaluation of Liver Fibrosis: A Concise Review
Afdhal, N. H., & Nunes, D. (2004) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2004.30110.x · Cited by 622
Assessment of biliary fibrosis by transient elastography in patients with PBC and PSC
Corpechot, C., El Naggar, A., Poujol-Robert, A., Ziol, M., Wendum, D., Chazouillères, O., de Lédinghen, V., Dhumeaux, D., Marcellin, P., Beaugrand, M., et al. (2006) · Hepatology · doi:10.1002/hep.21151 · Cited by 441
Metadata
- Authors
- Olsson, R., Hägerstrand, I., Broomé, U., Danielsson, A., Järnerot, G., Lööf, L., Prytz, H., Rydén, B. O., & Wallerstedt, S.
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 1995-10
- Volume
- 48
- Issue
- 10
- Pages
- 933-935
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- OpenAlex
- W2091071330
- Cited by
- 143
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sampling variability of percutaneous liver biopsy in primary sclerosing cholangitis. https://app.cochat.ai/papers/10.1136/jcp.48.10.933
- The paper
- Olsson, R., Hägerstrand, I., Broomé, U., Danielsson, A., Järnerot, G., Lööf, L., Prytz, H., Rydén, B. O., & Wallerstedt, S. (1995). Sampling variability of percutaneous liver biopsy in primary sclerosing cholangitis. Journal of Clinical Pathology. https://doi.org/10.1136/jcp.48.10.933
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.