Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 189

The DOI matches its Crossref record.

The clinical role of evoked potentials

Open access
Walsh, P · 2005 · Journal of Neurology, Neurosurgery & Psychiatry

Abstract

euro-electric responses to sensory stimuli can be readily and non-invasively recorded using averaging techniques first employed by Dawson in 1947. 1 The evoked responses can be quantified by measuring peak amplitudes and latencies, in the millisecond (ms) domain, and they provide numerical data that are quantitative extensions of the neurological examination.The clinical utility of evoked potentials (EPs) is based on their ability to: c demonstrate abnormal sensory system conduction, when the history and/or neurological examination is equivocal c reveal subclinical involvement of a sensory system (''silent'' lesions), particularly when demyelination is suggested by symptoms and/or signs in another area of the central nervous system c help define the anatomic distribution and give some insight into pathophysiology of a disease process c monitor changes in a patient's neurological status.In theory almost any sensory modality may be tested, although in routine clinical practice pattern reversal visual evoked potentials (VEPs), short latency somatosensory evoked potentials (SSEPs), and brainstem auditory evoked potentials (BSAEPs) are tested most frequently.Longer latency responses that are related to higher ''cognitive'' functions such as event related potentials (ERPs), contingent negative variant (CNV), and sensory potentials after stimulation with CO 2 lasers are not routinely used in clinical practice and are beyond the scope of this article.EPs have the advantages of being objective, often more sensitive than detailed neurological examination, and they can be recorded in patients who are anaesthetised or comatose.The latter fact, along with improvements in recording equipment, has led to newer applications in the operating theatre and intensive care unit (ICU)-at a time when the role of EPs in the assessment of multiple sclerosis has largely been replaced by magnetic resonance imaging (MRI).A recent evidence based review recommended that VEPs are probably useful and SSEPs are possibly useful in identifying patients who are at increased risk for developing clinically definite MS, but that there was insufficient evidence to recommend BSAEPs. 2 Disadvantages of EPs in clinical practice are that they are rarely disease specific and can be confounded by end organ disease (for example, VEPs may be abnormal in ocular disease, SSEPs in patients with peripheral neuropathy, and BSAEPs in conductive and sensorineural deafness), are affected by age, and require a degree of patient cooperation to obtain artefact-free recordings. VISUAL EVOKED POTENTIALS: WHAT ARE THEY? cVEPs provide a sensitive indication of abnormal conduction in the visual pathway.Increases in retino-striate conduction time caused by processes such as demyelination can be detected by measuring the latency of this cortical response.Abnormalities in the amplitude and waveform of the VEPs may also be caused by the loss of axons in the pathway.VEPs are therefore widely used in the investigation of demyelinating disease, optic neuritis, and other optic neuropathies.The standard clinical test involves the recording of the pattern reversal VEPs.The visual stimulus is a high contrast black-and-white checkerboard spanning the central 20 ˚-30 ˚of the visual field whose black and white squares periodically exchange places.The VEP is the averaged response to this reversal.Normal responses to binocular and monocular ''full field'' stimulation are illustrated in the upper part of fig 1.The responses are recorded from three electrodes spanning the occipital region with a mid frontal electrode as the voltage reference.The signal at the midline occipital electrode normally contains a prominent positive component which occurs approximately 100 ms after the pattern reversal (called P100).It is usually preceded by a smaller negative component with a latency of about 75 ms (N75).The waveforms at the lateral electrodes are rather variable and so the latency of P100 at the midline electrode is taken as the measure of retino-striate conduction time.The cursors in fig 1 show the mean latency for this group of normal subjects ¡2.5 SDs, the range used in our laboratory to define the range of normal variation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jnnp.2005.068130

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 189

Metadata

Authors
Walsh, P.
Venue
Journal of Neurology, Neurosurgery & Psychiatry
Publisher
BMJ
Published
2005-06-01
Volume
76
Issue
suppl_2
Pages
ii16-ii22
ISSN
0022-3050 (ISSN-L)
OpenAlex
W2148728440
Cited by
189
References
0
FWCI
1.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The clinical role of evoked potentials. https://app.cochat.ai/papers/10.1136/jnnp.2005.068130
The paper
Walsh, P. (2005). The clinical role of evoked potentials. Journal of Neurology, Neurosurgery & Psychiatry. https://doi.org/10.1136/jnnp.2005.068130

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.