Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record.

Comparison between the lumbar infusion and CSF tap tests to predict outcome after shunt surgery in suspected normal pressure hydrocephalus

Open access
Kahlon, B·2002·Journal of Neurology, Neurosurgery & Psychiatry

Abstract

OBJECTIVE: To compare the lumbar infusion test and the cerebrospinal fluid (CSF) tap test for predicting the outcome of shunt surgery in patients with suspected normal pressure hydrocephalus. METHODS: 68 patients with suspected normal pressure hydrocephalus were studied. The absence of preceding history indicated idiopathic disease in 75% of these. All patients were assessed twice with walking and psychometric tests before lumbar infusion test and tap test assessments. The lumbar infusion test was done using a constant infusion rate (0.80 ml/min) and regarded as positive if the steady state CSF plateau pressure reached levels of > 22 mm Hg (resistance to outflow > 14 mm Hg/ml/min). The tap test was regarded as positive if two or more of four different test items improved after CSF removal. As the variability in baseline test results was large, the better of two evaluations was used in comparisons with the results after CSF removal, as well as to evaluate the outcome after shunt surgery. Only patients with a positive lumbar infusion test or a positive tap test had surgery. RESULTS: The results of the CSF tap test and the lumbar infusion test agreed in only 45% of the patients. Of the total cohort, 47 (69%) had positive test results and were operated on; 45 (96%) of these reported subjective improvement, and postoperative assessments verified the improvements in 38 (81%). Improvements were highly significant in walking, memory, and reaction time tests (p < 0.001). Most of the patients improved by surgery (84%) were selected by a positive lumbar infusion test, and only 42% by a positive tap test. Positive predictive values were 80% for lumbar infusion test and 94% for tap test. The false negative predictions in the operated group were much higher (58%) with the tap test than with the lumbar infusion test (16%). CONCLUSIONS: Both the lumbar infusion test and the tap test can predict a positive outcome of shunt operations in unselected patients with suspected normal pressure hydrocephalus. The two tests are complementary and should be used together for optimal patient selection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/jnnp.73.6.721

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 195

Metadata

Authors
Kahlon, B.
Venue
Journal of Neurology, Neurosurgery & Psychiatry
Publisher
BMJ
Published
2002-12-01
Volume
73
Issue
6
Pages
721-726
ISSN
0022-3050 (ISSN-L)
OpenAlex
W2120001191
Cited by
195
References
0
FWCI
1.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison between the lumbar infusion and CSF tap tests to predict outcome after shunt surgery in suspected normal pressure hydrocephalus. https://app.cochat.ai/papers/10.1136/jnnp.73.6.721
The paper
Kahlon, B. (2002). Comparison between the lumbar infusion and CSF tap tests to predict outcome after shunt surgery in suspected normal pressure hydrocephalus. Journal of Neurology, Neurosurgery & Psychiatry. https://doi.org/10.1136/jnnp.73.6.721

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.