The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Impact of balloon guide catheter on technical and clinical outcomes: a systematic review and meta-analysis
Open accessAbstract
Background and purpose: Flow arrest with balloon guide catheters (BGCs) is becoming increasingly recognized as critical to optimizing patient outcomes for mechanical thrombectomy. We performed a systematic review and meta-analysis of the literature for studies that compared angiographic and clinical outcomes for patients who underwent mechanical thrombectomy with and without BGCs. Materials and methods: In April 2017 a literature search on BGC and mechanical thrombectomy for stroke was performed. All studies included patients treated with and without BGCs using modern techniques (ie, stent retrievers). Using random effects meta-analysis, we evaluated the following outcomes: first-pass recanalization, Thrombolysis In Cerebral Infarction (TICI) 3 recanalization, TICI 2b/3 recanalization, favorable outcome (modified Rankin Scale (mRS) 0–2), mortality, and mean number of passes and procedure time. Results: Five non-randomized studies of 2022 patients were included (1083 BGC group and 939 non-BGC group). Compared with the non-BGC group, patients treated with BGCs had higher odds of first-pass recanalization (OR 2.05, 95% CI 1.65 to 2.55), TICI 3 (OR 2.13, 95% CI 1.43 to 3.17), TICI 2b/3 (OR 1.54, 95% CI 1.21 to 1.97), and mRS 0–2 (OR 1.84, 95% CI 1.52 to 2.22). BGC-treated patients also had lower odds of mortality (OR 0.52, 95% CI 0.37 to 0.73) compared with non-BGC patients. The mean number of passes was significantly lower for BGC-treated patients (weighted mean difference −0.34, 95% CI−0.47 to −0.22). Mean procedure time was also significantly shorter for BGC-treated patients (weighted mean difference −7.7 min, 95% CI−9.0to −6.4). Conclusions: Non-randomized studies suggest that BGC use during mechanical thrombectomy for acute ischemic stroke is associated with superior clinical and angiographic outcomes. Further randomized trials are needed to confirm the results of this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evaluating non-randomised intervention studies
Deeks, J., Dinnes, J., D'Amico, R., Sowden, A., Sakarovitch, C., Song, F., Petticrew, M., & Altman, D. (2003) · Health Technology Assessment · doi:10.3310/hta7270 · Cited by 2,907
Cited by
Turc, G., Bhogal, P., Fischer, U., Khatri, P., Lobotesis, K., Mazighi, M., Schellinger, P. D., Toni, D., de Vries, J., White, P., et al. (2023) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2018-014569 · Cited by 611
Metadata
- Authors
- Brinjikji, W., Starke, R. M., Murad, M. H., Fiorella, D., Pereira, V. M., Goyal, M., & Kallmes, D. F.
- Venue
- Journal of NeuroInterventional Surgery
- Publisher
- BMJ
- Published
- 2017-07-28
- Volume
- 10
- Issue
- 4
- Pages
- 335-339
- ISSN
- 1759-8478 (ISSN-L)
- 1759-8486
- OpenAlex
- W2741675760
- Cited by
- 200
- References
- 1
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of balloon guide catheter on technical and clinical outcomes: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1136/neurintsurg-2017-013179
- The paper
- Brinjikji, W., Starke, R. M., Murad, M. H., Fiorella, D., Pereira, V. M., Goyal, M., & Kallmes, D. F. (2018). Impact of balloon guide catheter on technical and clinical outcomes: a systematic review and meta-analysis. Journal of NeuroInterventional Surgery. https://doi.org/10.1136/neurintsurg-2017-013179
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.