First-in-human, robotic-assisted neuroendovascular intervention
Open accessThe DOI matches its Crossref record.
Abstract
Robotic-assisted technology has been used as a tool to enhance open and minimally invasive surgeries as well as percutaneous coronary and peripheral vascular interventions. It offers many potential benefits, including increased procedural and technical accuracy as well as reduced radiation dose during fluoroscopic procedures. It also offers the potential for truly “remote” procedures. Despite these benefits, robotic technology has not yet been used in the neuroendovascular field, aside from diagnostic cerebral angiography. Here, we report the first robotic-assisted, therapeutic, neuroendovascular intervention performed in a human. This was a stent-assisted coiling procedure to treat a large basilar aneurysm. All intracranial steps, including stent placement and coil deployment, were performed with assistance from the CorPath© GRX Robotic System (Corindus, a Siemens Healthineers Company, Waltham, MA, USA). This represents a major milestone in the treatment of neurovascular disease and opens the doors for the development of remote robotic neuroendovascular procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Telerobotic neurovascular interventions with magnetic manipulation
Kim, Y., Genevriere, E., Harker, P., Choe, J., Balicki, M., Regenhardt, R. W., Vranic, J. E., Dmytriw, A. A., Patel, A. B., & Zhao, X. (2022) · Science Robotics · doi:10.1126/scirobotics.abg9907 · Cited by 422
Challenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Dexterous helical magnetic robot for improved endovascular access
Dreyfus, R., Boehler, Q., Lyttle, S., Gruber, P., Lussi, J., Chautems, C., Gervasoni, S., Berberat, J., Seibold, D., Ochsenbein-Kölble, N., et al. (2024) · Science Robotics · doi:10.1126/scirobotics.adh0298 · Cited by 185
Peng, Q., Wang, S., Han, J., Huang, C., Yu, H., Li, D., Qiu, M., Cheng, S., Wu, C., Cai, M., et al. (2024) · Research · doi:10.34133/research.0339 · Cited by 89
“Accessing the vascular system using catheters has revolutionized minimally invasive diagnostic and therapeutic procedures, providing numerous clinical benefits [1,2].”
BackgroundEndovascular Microrobotics for Neurointervention
Santiago-Dieppa, D. R., & Friend, J. (2024) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060523-010720 · Cited by 12
Metadata
- Authors
- Mendes Pereira, V., Cancelliere, N. M., Nicholson, P., Radovanovic, I., Drake, K. E., Sungur, J.-M., Krings, T., & Turk, A.
- Venue
- Journal of NeuroInterventional Surgery
- Publisher
- BMJ
- Published
- 2020-03-03
- Volume
- 12
- Issue
- 4
- Pages
- 338-340
- ISSN
- 1759-8478 (ISSN-L)
- 1759-8486
- OpenAlex
- W3010469249
- Cited by
- 151
- References
- 0
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: First-in-human, robotic-assisted neuroendovascular intervention. https://app.cochat.ai/papers/10.1136/neurintsurg-2019-015671.rep
- The paper
- Mendes Pereira, V., Cancelliere, N. M., Nicholson, P., Radovanovic, I., Drake, K. E., Sungur, J.-M., Krings, T., & Turk, A. (2020). First-in-human, robotic-assisted neuroendovascular intervention. Journal of NeuroInterventional Surgery. https://doi.org/10.1136/neurintsurg-2019-015671.rep
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.