CoChat

Associations between ambient, personal, and indoor exposure to fine particulate matter constituents in Dutch and Finnish panels of cardiovascular patients

Open access
Janssen, N A H, Lanki, T, Hoek, G, Vallius, M, de Hartog, J J, Van Grieken, R, Pekkanen, J, Brunekreef, B · 2005 · Occupational and Environmental Medicine
Cited by 129

The DOI matches its Crossref record.

Abstract

Aims:To assess the relation between ambient, indoor, and personal levels of PM 2.5 and its elemental composition for elderly subjects with cardiovascular disease. Methods:In the framework of a European Union funded study, panel studies were conducted in Amsterdam, the Netherlands and Helsinki, Finland. Outdoor PM 2.5 concentrations were measured at a fixed site. Each subject’s indoor and personal PM 2.5 exposure was measured biweekly for six months, during the 24 hour period preceding intensive health measurements. The absorbance of PM 2.5 filters was measured as a marker for diesel exhaust. The elemental content of more than 50% of the personal and indoor samples and all corresponding outdoor samples was measured using energy dispersive x ray fluorescence. Results:For Amsterdam and Helsinki respectively, a total of 225 and 238 personal, and 220 and 233 indoor measurements, were analysed from 36 and 46 subjects. For most elements, personal and indoor concentrations were lower than and highly correlated with outdoor concentrations. The highest correlations (median r>0.9) were found for sulfur and particle absorbance, which both represent fine mode particles from outdoor origin. Low correlations were observed for elements that represent the coarser part of the PM 2.5 particles (Ca, Cu, Si, Cl). Conclusions:The findings of this study provide support for using fixed site measurements as a measure of exposure to particulate matter in time series studies linking the day to day variation in particulate matter to the day to day variation in health endpoints, especially for components of particulate matter that are generally associated with fine particles and have few indoor sources. The high correlation for absorbance of PM 2.5 documents that this applies to particulate matter from combustion sources, such as diesel vehicles, as well.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/oem.2004.016618

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Janssen, N. A. H., Lanki, T., Hoek, G., Vallius, M., de Hartog, J. J., Van Grieken, R., Pekkanen, J., & Brunekreef, B.
Venue
Occupational and Environmental Medicine
Publisher
BMJ
Published
2005-11-18
Volume
62
Issue
12
Pages
868-877
ISSN
  • 0007-1072 (ISSN-L)
  • 1351-0711
  • 1470-7926
OpenAlex
W2112542634
Cited by
129
References
0
FWCI
6.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.