Development of a fibre size-specific job-exposure matrix for airborne asbestos fibres

Dement, J M, Kuempel, E D, Zumwalde, R D, Smith, R J, Stayner, L T, Loomis, D · 2008 · Occupational and Environmental Medicine
Cited by 55

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Objective: To develop a method for estimating fibre size-specific exposures to airborne asbestos dust for use in epidemiological investigations of exposure-response relations. Methods: Archived membrane filter samples collected at a Charleston, South Carolina asbestos textile plant during 1964–8 were analysed by transmission electron microscopy (TEM) to determine the bivariate diameter/length distribution of airborne fibres by plant operation. The protocol used for these analyses was based on the direct transfer method published by the International Standards Organization (ISO), modified to enhance fibre size determinations, especially for long fibres. Procedures to adjust standard phase contrast microscopy (PCM) fibre concentration measures using the TEM data in a job-exposure matrix (JEM) were developed in order to estimate fibre size-specific exposures. Results: A total of 84 airborne dust samples were used to measure diameter and length for over 18 000 fibres or fibre bundles. Consistent with previous studies, a small proportion of airborne fibres were longer than >5 μm in length, but the proportion varied considerably by plant operation (range 6.9% to 20.8%). The bivariate diameter/length distribution of airborne fibres was expressed as the proportion of fibres in 20 size-specific cells and this distribution demonstrated a relatively high degree of variability by plant operation. PCM adjustment factors also varied substantially across plant operations. Conclusions: These data provide new information concerning the airborne fibre characteristics for a previously studied textile facility. The TEM data demonstrate that the vast majority of airborne fibres inhaled by the workers were shorter than 5 μm in length, and thus not included in the PCM-based fibre counts. The TEM data were used to develop a new fibre size-specific JEM for use in an updated cohort mortality study to investigate the role of fibre dimension in the development of asbestos-related lung diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/oem.2007.033712

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 55

Metadata

Authors
Dement, J. M., Kuempel, E. D., Zumwalde, R. D., Smith, R. J., Stayner, L. T., & Loomis, D.
Venue
Occupational and Environmental Medicine
Publisher
BMJ
Published
2007-11-05
Volume
65
Issue
9
Pages
605-612
ISSN
  • 0007-1072 (ISSN-L)
  • 1351-0711
  • 1470-7926
OpenAlex
W2119986945
Cited by
55
References
1
FWCI
3.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Development of a fibre size-specific job-exposure matrix for airborne asbestos fibres. https://app.cochat.ai/papers/10.1136/oem.2007.033712
The paper
Dement, J. M., Kuempel, E. D., Zumwalde, R. D., Smith, R. J., Stayner, L. T., & Loomis, D. (2008). Development of a fibre size-specific job-exposure matrix for airborne asbestos fibres. Occupational and Environmental Medicine. https://doi.org/10.1136/oem.2007.033712

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.