Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 251

The DOI matches its Crossref record.

Audiometric notch as a sign of noise induced hearing loss

Open access
McBride, D I, Williams, S · 2001 · Occupational and Environmental Medicine

Abstract

OBJECTIVES: To investigate the relation between different types of exposure to noise and a classic sign of noise induced hearing loss (NIHL), the audiometric notch. METHODS: The study sample had exposure to both continuous and impulse noise and was drawn from a population of electrical transmission workers. Audiograms, taken as part of a hearing conservation programme, were read by three clinicians experienced in the assessment of NIHL. Working independently and using their clinical judgment, they were asked to identify localised increases in the threshold of hearing (audiometric notches) which they would attribute to noise, had a suitable history of exposure been elicited. Prevalent cases of NIHL were identified by the presence of a notch in either ear. Risk factors for NIHL were assessed by a questionnaire which sought information about exposure to air blast circuit breaker noise; firearms; explosions, and continuous noise. The odds of exposure to these factors in those with and without hearing loss were calculated, and odds ratios (ORs) and 95% confidence intervals (95% CIs) were estimated by logistic regression. RESULTS: Of the 648 questionnaires sent out 357 were returned, a response rate of 55%. Of these, at least two out of the three assessors identified 175 (49%) people with a notch at any audiometric frequency. There was no association between these cases and the NIHL risk factors identified by the questionnaire, but a further frequency specific analysis showed a small proportion of people (15 (4%)) with notches at 4 kHz who had the expected associations with exposure to noise and a significant OR for firearms of 4.25 (95% CI 1.28 to 14.1). The much larger proportion of people with 6 kHz notches (110 (31%)) did not show these associations. CONCLUSIONS: To diagnose NIHL it is important to elicit a detailed and accurate history of exposure to noise: although the notch at 4 kHz is a well established clinical sign and may be valuable in confirming the diagnosis, the 6 kHz notch is variable and of limited importance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/oem.58.1.46

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 251

Metadata

Authors
McBride, D. I., & Williams, S.
Venue
Occupational and Environmental Medicine
Publisher
BMJ
Published
2001-01-01
Volume
58
Issue
1
Pages
46-51
ISSN
  • 0007-1072 (ISSN-L)
  • 1351-0711
  • 1470-7926
OpenAlex
W2123207993
Cited by
251
References
0
FWCI
1.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Audiometric notch as a sign of noise induced hearing loss. https://app.cochat.ai/papers/10.1136/oem.58.1.46
The paper
McBride, D. I., & Williams, S. (2001). Audiometric notch as a sign of noise induced hearing loss. Occupational and Environmental Medicine. https://doi.org/10.1136/oem.58.1.46

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.