Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 194

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Artificial stone-associated silicosis: a rapidly emerging occupational lung disease

Open access
Hoy, Ryan F, Baird, Timothy, Hammerschlag, Gary, Hart, David, Johnson, Anthony R, King, Paul, Putt, Michael, Yates, Deborah H·2018·Occupational and Environmental Medicine

Abstract

Introduction: Artificial stone is an increasingly popular material used to fabricate kitchen and bathroom benchtops. Cutting and grinding artificial stone is associated with generation of very high levels of respirable crystalline silica, and the frequency of cases of severe silicosis associated with this exposure is rapidly increasing. Aim: To report the characteristics of a clinical series of Australian workers with artificial stone-associated silicosis. Methods: Respiratory physicians voluntarily reported cases of artificial stone-associated silicosis identified in their clinical practices. Physicians provided information including occupational histories, respiratory function tests, chest radiology and histopathology reports, when available. Results: Seven male patients were identified with a median age of 44 years (range 26–61). All were employed in small kitchen and bathroom benchtop fabrication businesses with an average of eight employees (range 2–20). All workplaces primarily used artificial stone, and dust control measures were poor. All patients were involved in dry cutting artificial stone. The median duration of exposure prior to symptoms was 7 years (range 4–10). Six patients demonstrated radiological features of progressive massive fibrosis. These individuals followed up over a median follow-up period of 16 months (IQR 21 months) demonstrated rapid decline in prebronchodilator forced expiratory volume in 1 s of 386 mL/year (SD 204 mL) and forced vital capacity of 448 mL/year (SD 312 mL). Conclusions: This series of silicosis in Australian workers further demonstrates the risk-associated high-silica content artificial stone. Effective dust control and health surveillance measures need to be stringently implemented and enforced in this industry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/oemed-2017-104428

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 194

Metadata

Authors
Hoy, R. F., Baird, T., Hammerschlag, G., Hart, D., Johnson, A. R., King, P., Putt, M., & Yates, D. H.
Venue
Occupational and Environmental Medicine
Publisher
BMJ
Published
2017-09-07
Volume
75
Issue
1
Pages
3-5
ISSN
  • 0007-1072 (ISSN-L)
  • 1351-0711
  • 1470-7926
OpenAlex
W2753784032
Cited by
194
References
2
FWCI
10.33
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Artificial stone-associated silicosis: a rapidly emerging occupational lung disease. https://app.cochat.ai/papers/10.1136/oemed-2017-104428
The paper
Hoy, R. F., Baird, T., Hammerschlag, G., Hart, D., Johnson, A. R., King, P., Putt, M., & Yates, D. H. (2018). Artificial stone-associated silicosis: a rapidly emerging occupational lung disease. Occupational and Environmental Medicine. https://doi.org/10.1136/oemed-2017-104428

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.