Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 187

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Design of a safer approach to intravenous drug infusions: failure mode effects analysis

Open access
Apkon, M · 2004 · Quality and Safety in Health Care

Abstract

OBJECTIVES: A set of standard processes was developed for delivering continuous drug infusions in order to improve (1) patient safety; (2) efficiency in staff workflow; (3) hemodynamic stability during infusion changes, and (4) efficient use of resources. Failure modes effects analysis (FMEA) was used to examine the impact of process changes on the reliability of delivering drug infusions. SETTING: An 11 bed multidisciplinary pediatric ICU in the children's hospital of an academic medical center staffed by board certified pediatric intensivists. The hospital uses computerized physician order entry for all medication orders. METHODS: A multidisciplinary team characterized key elements of the drug infusion process. The process was enhanced to increase overall reliability and the original and revised processes were compared using FMEA. Resource consumption was estimated by reviewing purchasing and pharmacy records for the calendar year after full implementation of the revised process. Staff satisfaction was evaluated using an anonymous questionnaire administered to staff nurses in the ICU and pediatric residents who had rotated through the ICU. RESULTS: The original process was characterized by six elements: selecting the drug; selecting a dose; selecting an infusion rate; calculating and ordering the infusion; preparing the infusion; programming the infusion pump and delivering the infusion. The following practice changes were introduced: standardizing formulations for all infusions; developing database driven calculators; extending infusion hang times from 24 to 72 hours; changing from bedside preparation by nurses to pharmacy prepared or premanufactured solutions. FMEA showed that the last three elements of the original process had high risk priority numbers (RPNs) of >225 whereas the revised process had no elements with RPNs >100. The combined effect of prolonging infusion hang times, preparation in the pharmacy, and purchasing premanufactured solutions resulted in 1500 fewer infusions prepared by nurses per year. Nursing staff expressed a significant preference and pediatric residents unanimously expressed a strong preference for the revised process. CONCLUSIONS: Standardization of infusion delivery reduced the frequency for completing the most unreliable elements of the process and reduced the riskiness of the individual elements. Both contribute to a safer system.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/qhc.13.4.265

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Apkon, M.
Venue
Quality and Safety in Health Care
Publisher
BMJ
Published
2004-08-01
Volume
13
Issue
4
Pages
265-271
ISSN
  • 1475-3898 (ISSN-L)
  • 1475-3901
OpenAlex
W2125610376
Cited by
187
References
1
FWCI
9.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.