Insights from the sharp end of intravenous medication errors: implications for infusion pump technology
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Intravenous (IV) medication errors are a common type of error identified in hospitals and can lead to considerable harm. Over the past 20 years there have been several hundred FDA reported incidents involving IV pumps, many of which have led to patient deaths. OBJECTIVE: To determine the actual types, frequency, and severity of medication errors associated with IV pumps. To evaluate the likelihood that smart pump technology without an interface to other systems could have prevented errors. METHODS: Using a point prevalence approach, investigators prospectively compared the medication, dose, and infusion rate on the IV pump with the prescribed medication, doses, and rate in the medical record. Preventability with smart pump technology was retrospectively determined based on a rigorous definition of currently available technology. RESULTS: A total of 426 medications were observed infusing through an IV pump. Of these, 285 (66.9%) had one or more errors associated with their administration. There were 389 documented errors overall; 37 were "rate deviation" errors and three of these were judged to be due to a programming mistake. Most of the documented events would not have caused patient harm (NCC MERP category C). Only one error would have been prevented by smart pump technology without additional interface and software capabilities. CONCLUSION: Medication errors associated with IV pumps occur frequently, have the potential to cause harm, and are epidemiologically diverse. Smart pumps are a necessary component of a comprehensive safe medication system. However, currently available smart pumps will fail to generate meaningful improvements in patient safety until they can be interfaced with other systems such as the electronic medical record, computerized prescriber order entry, bar coded medication administration systems, and pharmacy information systems. Future research should focus on the effectiveness of new technology in preventing latent and active errors, and on new types of error that any technology can introduce.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human error: models and management
Reason, J. (2000) · BMJ · doi:10.1136/bmj.320.7237.768 · Cited by 5,665
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127 · cited 2×
“2 5 They are also the most dangerous type of medication error as they are least likely to be intercepted 6 and often involve medications with a narrow therapeutic range (such as ‘‘high alert medications’’).”
BackgroundMedication Errors and Adverse Drug Events in Pediatric Inpatients
Kaushal, R. (2001) · JAMA · doi:10.1001/jama.285.16.2114 · Cited by 1,917
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
The Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260
Human error: models and management
Reason, J. (2000) · Western Journal of Medicine · doi:10.1136/ewjm.172.6.393 · Cited by 798
Detecting Adverse Events Using Information Technology
Bates, D. W., Evans, R. S., Murff, H., Stetson, P. D., Pizziferri, L., & Hripcsak, G. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1074 · Cited by 467
Ethnographic study of incidence and severity of intravenous drug errors
Taxis, K., & Barber, N. (2003) · BMJ · doi:10.1136/bmj.326.7391.684 · Cited by 373
The Epidemiology of Prescribing Errors: The Potential Impact of Computerized Prescriber Order Entry
Bobb, A., Gleason, K., Husch, M., Feinglass, J., Yarnold, P. R., & Noskin, G. A. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.7.785 · Cited by 359 · cited 2×
“21 These categories, in ascending order of severity, include capacity to cause error (A), an error occurred but did not reach the patient (B), errors unlikely to cause harm despite reaching the patient (C), errors that would have required increased monitoring to preclude harm (D), errors likely to…”
BackgroundMethodSelf-citationPhysician Reporting Compared with Medical-Record Review to Identify Adverse Medical Events
O'Neil, A. C., Petersen, L. A., Cook, E. F., Bates, D. W., Lee, T. H., & Brennan, T. A. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-119-5-199309010-00004 · Cited by 315
Cited by
Using Storytelling to Elicit Design Guidance for Medical Devices
Gausepohl, K., Winchester, W. W., Arthur, J. D., & Smith-Jackson, T. (2011) · Ergonomics in Design The Quarterly of Human Factors Applications · doi:10.1177/1064804611408017 · Cited by 13
“In fact, the design may facilitate operator error (Lane, Stanton, & Harrison, 2006), and a single “slip-of-the-finger” error can deliver unsafe levels of medication (Husch et al., 2005).”
Background
Metadata
- Authors
- Husch, M.
- Venue
- Quality and Safety in Health Care
- Publisher
- BMJ
- Published
- 2005-04-01
- Volume
- 14
- Issue
- 2
- Pages
- 80-86
- ISSN
- 1475-3898 (ISSN-L)
- 1475-3901
- OpenAlex
- W2144221998
- Cited by
- 244
- References
- 23
- FWCI
- 14.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Insights from the sharp end of intravenous medication errors: implications for infusion pump technology. https://app.cochat.ai/papers/10.1136/qshc.2004.011957
- The paper
- Husch, M. (2005). Insights from the sharp end of intravenous medication errors: implications for infusion pump technology. Quality and Safety in Health Care. https://doi.org/10.1136/qshc.2004.011957
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.