CoChat

Accuracy of FENOfor diagnosing asthma: a systematic review

Open access
Karrasch, Stefan, Linde, Klaus, Rücker, Gerta, Sommer, Harriet, Karsch-Völk, Marlies, Kleijnen, Jos, Jörres, Rudolf A, Schneider, Antonius · 2017 · Thorax
Cited by 160

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background Measurement of FENO might substitute bronchial provocation for diagnosing asthma. We aimed to investigate the diagnostic accuracy of FENO measurement compared with established reference standard. Methods Systematic review and diagnostic meta-analysis. Data sources were Medline, Embase and Scopus up to 29 November 2015. Sensitivity and specificity were estimated using a bivariate model. Additionally, summary receiver-operating characteristic curves were estimated. Results 26 studies with 4518 participants (median 113) were included. Risk of bias was considered low for six of seven items in five studies and for five items in seven studies. The overall sensitivity in the meta-analysis was 0.65 (95% CI 0.58 to 0.72), the overall specificity 0.82 (0.76 to 0.86), the diagnostic OR 9.23 (6.55 to 13.01) and the area under the curve 0.80 (0.77 to 0.85). In meta-regression analyses, higher cut-off values were associated with increasing specificity (OR 1.46 per 10 ppb increase in cut-off) while there was no association with sensitivity. Sensitivities varied significantly within the different FENO devices, but not specificities. Neither prevalence, age, use of bronchoprovocation in >90% of participants or as exclusive reference standard test, nor risk of bias were significantly associated with diagnostic accuracy. Conclusions There appears to be a fair accuracy of FENO for making the diagnosis of asthma. The overall specificity was higher than sensitivity, which indicates a higher diagnostic potential for ruling in than for ruling out the diagnosis of asthma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thoraxjnl-2016-208704

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 160

Metadata

Authors
Karrasch, S., Linde, K., Rücker, G., Sommer, H., Karsch-Völk, M., Kleijnen, J., Jörres, R. A., & Schneider, A.
Venue
Thorax
Publisher
BMJ
Published
2016-07-07
Volume
72
Issue
2
Pages
109-116
ISSN
  • 0040-6376 (ISSN-L)
  • 1468-3296
OpenAlex
W2472937739
Cited by
160
References
6
FWCI
2.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of FENOfor diagnosing asthma: a systematic review. https://app.cochat.ai/papers/10.1136/thoraxjnl-2016-208704
The paper
Karrasch, S., Linde, K., Rücker, G., Sommer, H., Karsch-Völk, M., Kleijnen, J., Jörres, R. A., & Schneider, A. (2017). Accuracy of FENOfor diagnosing asthma: a systematic review. Thorax. https://doi.org/10.1136/thoraxjnl-2016-208704

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.