CoChat

Neural respiratory drive, pulmonary mechanics and breathlessness in patients with cystic fibrosis

Open access
Reilly, C. C., Ward, K., Jolley, C. J., Lunt, A. C., Steier, J., Elston, C., Polkey, M. I., Rafferty, G. F., Moxham, J. · 2011 · Thorax
Cited by 126

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Neural respiratory drive (NRD) measured from the diaphragm electromyogram (EMGdi) reflects the load/capacity balance of the respiratory muscle pump and is a marker of lung disease severity. EMGdi measurement is invasive, but recording the EMG from the parasternal intercostal muscles using surface electrodes (sEMGpara) could provide a non-invasive method of assessing NRD and disease severity. Objectives To test the hypothesis that NRD measured by sEMGpara correlates with EMGdi, to provide an index of disease severity in cystic fibrosis (CF) and to relate to exercise-induced breathlessness. METHODS: 15 patients with CF (mean forced expiratory volume in 1 s (FEV(1)) 53.5% predicted) and 15 age-matched healthy controls were studied. sEMGpara and EMGdi were recorded at rest and during exercise. sEMGpara was recorded using surface electrodes and EMGdi using a multipair oesophageal electrode catheter. Signals were normalised using the peak EMG recorded during maximum respiratory manoeuvres and expressed as EMG%max. The respiratory pattern, metabolic data, oesophageal and gastric pressures and Borg scores were also recorded. RESULTS: Mean (SD) resting sEMGpara%max and EMGdi%max were higher in patients with CF than in controls (13.1 (7)% and 18.5 (7.5)% vs 5.8 (3)% and 7.5 (2)%, respectively, p<0.001). In the patients with CF, resting sEMGpara%max and EMGdi%max were related to the degree of airways obstruction (FEV(1)) (r = -0.91 and r = -0.82, both p<0.001), hyperinflation (r = 0.63 and r = 0.56, both p<0.001) and dynamic lung compliance (r = -0.53 and r = -0.59, both p<0.001). During exercise, sEMGpara%max and EMGdi%max were strongly correlated with breathlessness in the patients with CF before (r = 0.906, p<0.001) and after (r = 0.975, p<0.001) the onset of neuromechanical dissociation. CONCLUSION: sEMGpara%max provides a non-invasive marker of neural drive, which reflects disease severity and exercise-induced breathlessness in CF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.2010.142646

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 126

Metadata

Authors
Reilly, C. C., Ward, K., Jolley, C. J., Lunt, A. C., Steier, J., Elston, C., Polkey, M. I., Rafferty, G. F., & Moxham, J.
Venue
Thorax
Publisher
BMJ
Published
2011-02-01
Volume
66
Issue
3
Pages
240-246
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2149957054
Cited by
126
References
4
FWCI
5.44
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.