Ventilator modes and settings during non-invasive ventilation: effects on respiratory events and implications for their identification
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Compared with invasive ventilation, non-invasive ventilation (NIV) has two unique characteristics: the non-hermetic nature of the system and the fact that the ventilator-lung assembly cannot be considered as a single-compartment model because of the presence of variable resistance represented by the upper airway. When NIV is initiated, the ventilator settings are determined empirically based on a clinical evaluation and diurnal blood gas variations. However, NIV is predominantly applied during sleep. Consequently, to assess overnight patient-machine 'agreement' and efficacy of ventilation, more specific and sophisticated monitoring is needed. The effectiveness of NIV might therefore be more correctly assessed by sleep studies than by daytime assessment. The most available and simple monitoring can be done from flow and pressure curves from the mask or the ventilator circuit. Examination of these tracings can give useful information to evaluate if the settings chosen by the operator were the right ones for that patient. However, as NIV allows a large range of ventilatory parameters and settings, it is mandatory to have information about this to better understand patient-ventilator interaction. Ventilatory modality, mode of triggering, pressurisation slope, use or not of positive end expiratory pressure and type of exhalation as well as ventilator performances may all have physiological consequences. Leaks and upper airway resistance variations may, in turn, modify these patterns. This article discusses the equipment available for NIV, analyses the effect of different ventilator modes and settings and of exhalation and connecting circuits on ventilatory traces and gives the background necessary to understand their impact on nocturnal monitoring of NIV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Cited by
Gonzalez-Bermejo, J., Perrin, C., Janssens, J. P., Pepin, J. L., Mroue, G., Léger, P., Langevin, B., Rouault, S., Rabec, C., Rodenstein, D., et al. (2012) · Thorax · doi:10.1136/thx.2010.142653 · Cited by 176
Self-citationLong-Term Ventilation in Neuromuscular Patients: Review of Concerns, Beliefs, and Ethical Dilemmas
Crimi, C., Pierucci, P., Carlucci, A., Cortegiani, A., & Gregoretti, C. (2019) · Respiration · doi:10.1159/000495941 · Cited by 46
Metadata
- Authors
- Rabec, C., Rodenstein, D., Leger, P., Rouault, S., Perrin, C., Gonzalez-Bermejo, J., & on behalf of the SomnoNIV group
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2010-10-14
- Volume
- 66
- Issue
- 2
- Pages
- 170-178
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2135934914
- Cited by
- 158
- References
- 1
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ventilator modes and settings during non-invasive ventilation: effects on respiratory events and implications for their identification. https://app.cochat.ai/papers/10.1136/thx.2010.142661
- The paper
- Rabec, C., Rodenstein, D., Leger, P., Rouault, S., Perrin, C., Gonzalez-Bermejo, J., & on behalf of the SomnoNIV group. (2011). Ventilator modes and settings during non-invasive ventilation: effects on respiratory events and implications for their identification. Thorax. https://doi.org/10.1136/thx.2010.142661
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.