Cited by 63Chronic Obstructive Pulmonary Disease (COPD) ResearchAsthma and respiratory diseasesOccupational and environmental lung diseases

Relation between abnormalities in the chest radiograph and changes in pulmonary function in chronic bronchitis and emphysema

Open access
Simon, G., Pride, N. B., Jones, N. L., Raimondi, A. C.·1973·Thorax

Abstract

Chest radiographs of 101 patients with chronic airflow obstruction were assessed for evidence of over-inflation (increased retrosternal space, low diaphragm, and increased total lung capacity), pulmonary hypertension (increase in size of heart and major pulmonary vessels) and attenuation of medium-sized pulmonary vessels. The radiological abnormalities were related to the alterations in pulmonary function. When the position of the diaphragm was low or the retrosternal space was 4·5 cm or more the average FEV1 was below 1·0 litre, but severe impairment of the FEV1 could be present when the position and contour of the diaphragm were normal and the retrosternal space was 2·5 cm or less. The radiological method for estimating total lung capacity agreed well with the results obtained with body plethysmography, but there was not a close correlation between the standard radiological signs of over-inflation and a large total lung capacity. When the radiograph showed widespread vascular attenuation as well as over-inflation the impairment in FEV1 and other tests of pulmonary function was considerably more severe than when the radiograph showed over-inflation alone. Severe reduction in transfer factor was usually associated with changes in the pulmonary vessels. It is concluded that the radiological diagnosis of widespread emphysema can be made with confidence only when there is attenuation of pulmonary vessels as well as evidence of over-inflation. In attempting to diagnose emphysema in life all available clinical and functional data should be considered in conjunction with the radiographic appearances.

Integrity signals

Registry

Crossref · 10.1136/thx.28.1.15

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Radiographic techniques are not commonly used clinically to measure static hyperinflation in COPD because of a lack of standardization.

    “Finally, because of a lack of standardization, radiographic techniques144–147 are not commonly used clinically to measure static hyperinflation in COPD.32”

Cited by

Sorted by citations

Authors
Simon, G., Pride, N. B., Jones, N. L., & Raimondi, A. C.
Affiliations
Hammersmith Hospital (GB)
Venue
Thorax
Publisher
BMJ
Published
1973-01-01
Volume
28
Issue
1
Pages
15-23
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2041374679
Cited by
63
References
0
Citations by year
2026: 1 · 2024: 1 · 2023: 2 · 2022: 1 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 3 · 2016: 1 · 2014: 3 · 2013: 1 · 2012: 2
FWCI
3.04
Type
journal article
Language
en
Open access
Locations
  • Thorax (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
  • Health Sciences › Medicine › Physiology › Asthma and respiratory diseases
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
Keywords
chronic bronchitis, emphysema, chest radiography, lung function, diaphragm position, total lung capacity, pulmonary hypertension, FEV1, transfer factor, chronic airflow obstruction
MeSH terms
Bronchitis, Carbon Dioxide, Chronic Disease, Diaphragm, Humans, Hypertension, Pulmonary, Lung, Male, Middle Aged, Partial Pressure, Plethysmography, Whole Body, Pulmonary Artery, Pulmonary Diffusing Capacity, Pulmonary Emphysema, Radiography, Respiration, Spirometry, Vital Capacity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review