The DOI matches its Crossref record.
Factors influencing the size distribution of aerosols from jet nebulisers.
Open accessAbstract
The size distribution of saline and bronchodilator (terbutaline) aerosol droplets generated from four widely used jet nebulisers (Acorn, Upmist, Turret, and Inspiron Mini-neb) has been measured with a Malvern 2200 Laser Particle Sizer. The mass median diameter of aerosol droplets generated by each nebuliser was strongly influenced by the driving flow rate of compressed air. By increasing the flow rate from 4 to 8 1 min-1 mass median diameters were halved (p less than 0.01) and there was an increase in the mass of aerosol within the optimum respirable range (less than 5 micron). To achieve this range the following individual flow rates were required: Turret 4 1 min-1, Acorn and Upmist 6 1 min-1, and Inspiron Mini-neb 8 1 min-1. A significant inverse relation (p less than 0.001) was found between mass median diameter and the geometric standard deviation, indicating that the aerosols were smaller but more heterodisperse at high flow rates. Changes in drug concentration had little effect on aerosol size. In 72% of the nebulisations followed to dryness there was no significant change in mass median diameter during the course of nebulisation and in the remainder it was less than 1.3 micron.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The science of nebulised drug delivery
O'Callaghan, C., & Barry, P. W. (1997) · Thorax · doi:10.1136/thx.52.2008.s31 · Cited by 293
Inhaled nebulized nitrite is a hypoxia-sensitive NO-dependent selective pulmonary vasodilator
Hunter, C. J., Dejam, A., Blood, A. B., Shields, H., Kim-Shapiro, D. B., Machado, R. F., Tarekegn, S., Mulla, N., Hopper, A. O., Schechter, A. N., et al. (2004) · Nature Medicine · doi:10.1038/nm1109 · Cited by 281
Metadata
- Authors
- Clay, M. M., Pavia, D., Newman, S. P., & Clarke, S. W.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1983-10-01
- Volume
- 38
- Issue
- 10
- Pages
- 755-759
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2016406733
- Cited by
- 203
- References
- 0
- FWCI
- 12.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors influencing the size distribution of aerosols from jet nebulisers. https://app.cochat.ai/papers/10.1136/thx.38.10.755
- The paper
- Clay, M. M., Pavia, D., Newman, S. P., & Clarke, S. W. (1983). Factors influencing the size distribution of aerosols from jet nebulisers. Thorax. https://doi.org/10.1136/thx.38.10.755
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.