Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 180

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Performance, ventilation, and oxygen consumption in three different types of exercise test in patients with chronic obstructive lung disease.

Open access
Swinburn, C R, Wakefield, J M, Jones, P W · 1985 · Thorax

Abstract

Seventeen patients (six men and 11 women, mean age 66 years) with severe chronic obstructive lung disease (mean FEV1 0.8 (SD 0.3)1) performed three different types of exercise test on four occasions within one week. Three daily doses of placebo tablets were given between the third and fourth attempt at each test. The tests were the 12 minute walking test, a fixed rate and height paced step test, and a cycle ergometer test in which the work rate was increased by 10 watts each minute. Performance increased significantly (p less than 0.01) between the first and fourth attempts in each type of test (12 min walking distance 16% (SD 20%); steps climbed 96% (74%); duration of cycling 29% (41%]. There was a trend for the increase in performance between successive attempts to become progressively smaller but this was not significant. No effect of placebo on exercise performance was detected. The greatest intersubject range of performance was seen in the step test (14-126 steps) and the least in the walking test (438-1014 m). Significant correlations (p less than 0.01) were observed between performance in all three types of exercise test, but the correlations found between the results of the various tests of exercise performance and the FEV1 and the FVC were either weak (p less than 0.05) or non-significant. Ventilation (VE) and oxygen consumption (VO2) were subsequently measured and compared in eight patients during all three types of exercise test. Both the VE and the VO2 that were achieved in the step test were significantly greater than in either the cycle or the walking test. No patient was able to reach and sustain steady state values of VE and VO2 in the step test, whereas a steady state for both VE and VO2 was reached and sustained by all eight patients in the walking test. It is suggested that at least three practice attempts at any exercise test should be made before the introduction of either placebo or specific pharmacological treatment and that even then it may be necessary to allow for the effects of further repeated testing in the assessment of the results of treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.40.8.581

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 180

Metadata

Authors
Swinburn, C. R., Wakefield, J. M., & Jones, P. W.
Venue
Thorax
Publisher
BMJ
Published
1985-08-01
Volume
40
Issue
8
Pages
581-586
ISSN
0040-6376 (ISSN-L)
OpenAlex
W1991830682
Cited by
180
References
1
FWCI
4.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.