Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 202

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Nocturnal hypoxaemia and quality of sleep in patients with chronic obstructive lung disease.

Open access
Cormick, W, Olson, L G, Hensley, M J, Saunders, N A · 1986 · Thorax

Abstract

Fifty patients with chronic obstructive lung disease were questioned about their sleep quality and their responses were compared with those of 40 similarly aged patients without symptomatic lung disease. Patients with chronic obstructive lung disease reported more difficulty in getting to sleep and staying asleep and more daytime sleepiness than the control group. More than twice as many patients (28%) as controls (10%) reported regular use of hypnotics. In a subgroup of 16 patients with chronic obstructive lung disease (mean FEV1 0.88 (SD 0.44) sleep, breathing, and oxygenation were measured to examine the relationship between night time hypoxaemia and sleep quality. Sleep architecture was disturbed in most patients, arousals occurring from three to 46 times an hour (mean 15 (SD 14)/h). Arterial hypoxaemia during sleep was common and frequently severe. The mean (SD) arterial oxygen saturation (SaO2) at the onset of sleep was 91% (7%). Nine patients spent at least 40% of cumulative sleeping time at an SaO2 of less than 90% and six of these patients spent 90% of sleeping time below this level. Only four of 15 patients did not develop arterial desaturation during sleep. The mean minimum SaO2 during episodes of desaturation was less in rapid eye movement (REM) sleep (72% (17%)) than in non-REM sleep (78% (10%), p less than 0.05). The predominant breathing abnormality associated with desaturation was hypoventilation; only one patient had obstructive sleep apnoea. Arousals were related to oxygenation during sleep such that the poorer a patient's arterial oxygenation throughout the night the more disturbed his sleep (arousals/h v SaO2 at or below which 40% of the total sleep time was spent: r = 0.71, p less than 0.01). Hypoxaemia during sleep was related to waking values of SaO2 and PaCO2 but not to other daytime measures of lung function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.41.11.846

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Cormick, W., Olson, L. G., Hensley, M. J., & Saunders, N. A.
Venue
Thorax
Publisher
BMJ
Published
1986-11-01
Volume
41
Issue
11
Pages
846-854
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2121762803
Cited by
202
References
1
FWCI
0.69
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nocturnal hypoxaemia and quality of sleep in patients with chronic obstructive lung disease. https://app.cochat.ai/papers/10.1136/thx.41.11.846
The paper
Cormick, W., Olson, L. G., Hensley, M. J., & Saunders, N. A. (1986). Nocturnal hypoxaemia and quality of sleep in patients with chronic obstructive lung disease. Thorax. https://doi.org/10.1136/thx.41.11.846

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.