The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Short term variability in FEV1 and bronchodilator responsiveness in patients with obstructive ventilatory defects.
Open accessAbstract
Short term variability in FEV1 and responsiveness to inhaled bronchodilator were measured in 150 patients with obstructive ventilatory defects. The range of initial FEV1 was 0.5-4.71 and the natural variability over a 20 minute period when expressed in absolute terms was similar over the entire range, and differed insignificantly from that found in normal subjects. The increase in FEV1 and vital capacity (VC) required to exclude natural variability with 95% confidence in these patients was 160 ml and 330 ml respectively. Natural variability when expressed in percentage terms was negatively correlated with the level of FEV1 recorded. The analysis of changes in FEV1 and VC after administration of bronchodilator used absolute and percentage criteria for response. The number of responders differed considerably according to the criterion used. In those defined by the absolute criterion as responders there was no evidence that size of response was related to level of FEV1. Percentage criteria have traditionally been used to identify responses to bronchodilator that may be clinically useful, while absolute criteria, although statistically valid, have not been favoured. Reappraisal of the criteria used and their limitations and implications is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
Robust Tests for the Equality of Variances
Brown, M. B., & Forsythe, A. B. (1974) · Journal of the American Statistical Association · doi:10.1080/01621459.1974.10482955 · Cited by 3,216
Cited by
Interpretative strategies for lung function tests
Pellegrino, R., Viegi, G., Brusasco, V., Crapo, R. O., Burgos, F., Casaburi, R., Coates, A., van der Grinten, C. P. M., Gustafsson, P., Hankinson, J., et al. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00035205 · Cited by 5,945
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
Lung Function Testing: Selection of Reference Values and Interpretative Strategies
(1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.5.1202 · Cited by 2,510
British Guideline on the Management of Asthma
British Thoracic Society Scottish Intercollegiate Guidelines Network (2008) · Thorax · doi:10.1136/thx.2008.097741 · Cited by 2,021
Lung Function Testing: Selectionof reference Values and Interpretative Strategies
Miller, A. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.5_pt_1.1368b · Cited by 1,426
Metadata
- Authors
- Tweeddale, P. M., Alexander, F., & McHardy, G. J.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1987-07-01
- Volume
- 42
- Issue
- 7
- Pages
- 487-490
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2108401555
- Cited by
- 177
- References
- 2
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.