The DOI matches its Crossref record.
Portable liquid oxygen and exercise ability in severe respiratory disability.
Open accessAbstract
BACKGROUND: The development of portable liquid oxygen systems, capable of delivering high flow rate oxygen for long periods, justifies reassessment of the value of supplemental oxygen to aid exercise tolerance in patients with chronic respiratory insufficiency. The type of exercise test and the low oxygen flow rates previously used may account for the variable and often poor responses to supplemental oxygen reported in earlier studies. METHODS: The walking tolerance of 30 patients with severe respiratory disability was measured while they were breathing air and increasing doses of supplemental oxygen (2, 4, 6 1/min) by using both the standard six minute walking test and an endurance walking test. To assess the initial learning effect and repeatability of the walking tests, three six minute walks and three endurance walks were performed on day 1 and a single walk of each type on days 2, 3, and 14. In addition, oxygen dosing studies were performed on days 2 and 3 after the initial baseline walking tests. Each dosing study comprised four endurance walking tests or four six minute walking tests with patients breathing either air at a flow rate of 4 1/min from a portable cylinder or supplemental oxygen at a flow rate of 2, 4 or 6 1/min from a portable liquid oxygen supply. The order of the tests was randomised. Walking distance with each flow rate of oxygen was compared with walking distance with patients carrying cylinder air and for the initial unburdened walks. Breathlessness was assessed by visual analogue scoring on completion of each walk. RESULTS: Exercise ability and breathlessness were significantly improved with supplemental oxygen and this benefit outweighed the reduction in performance resulting from carrying the portable device. Supplemental oxygen at flow rates of 2, 4, and 6 1/min increased mean endurance walking distances by 37.9%, 67.7% and 85.0% and six minute walking distances by 19.2%, 34.5%, and 36.3% by comparison with distances when the patient was carrying air with a flow rate of 4 1/min. The additional work of carrying the portable gas supply reduced endurance walking distance by 22.2% and six minute walking distance by 14.1% by comparison with a baseline unburdened walk. Comparison of supplemental oxygen at 2, 4, and 6 1/min with the baseline unburdened performance showed increased endurance walking distances of 7.3%, 30.4%, and 43.9% and six minute walking distances of 2.3%, 15.5%, and 17.0%. Walking distance was increased by more than 50% by comparison with an unburdened walk in seven patients with the endurance walking test but in only three patients with the six minute walking test. The benefit was similar in patients with obstructive and with interstitial lung disease. Individual responses were variable and only desaturation during the baseline walk in patients with obstructive lung disease had any predictive value for benefit with oxygen. CONCLUSION: As there was no clear relation between response to oxygen therapy and the patients' characteristics, assessment for supplemental oxygen therapy will depend on exercise testing. It is suggested that portable oxygen should be considered only if a patient shows a 50% improvement in exercise ability with high flow rate oxygen (4-6 1/min) by comparison with an unburdened walk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
Reference Equations for the Six-Minute Walk in Healthy Adults
ENRIGHT, P. L., & SHERRILL, D. L. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.5.9710086 · Cited by 2,204
Singh, S. J., Puhan, M. A., Andrianopoulos, V., Hernandes, N. A., Mitchell, K. E., Hill, C. J., Lee, A. L., Camillo, C. A., Troosters, T., Spruit, M. A., et al. (2014) · European Respiratory Journal · doi:10.1183/09031936.00150414 · Cited by 935
Outcomes for COPD pharmacological trials: from lung function to biomarkers
Cazzola, M., MacNee, W., Martinez, F. J., Rabe, K. F., Franciosi, L. G., Barnes, P. J., Brusasco, V., Burge, P. S., Calverley, P. M. A., Celli, B. R., et al. (2008) · European Respiratory Journal · doi:10.1183/09031936.00099306 · Cited by 858
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
Metadata
- Authors
- Leach, R. M., Davidson, A. C., Chinn, S., Twort, C. H., Cameron, I. R., & Bateman, N. T.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1992-10-01
- Volume
- 47
- Issue
- 10
- Pages
- 781-789
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2036063898
- Cited by
- 160
- References
- 0
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Portable liquid oxygen and exercise ability in severe respiratory disability. https://app.cochat.ai/papers/10.1136/thx.47.10.781
- The paper
- Leach, R. M., Davidson, A. C., Chinn, S., Twort, C. H., Cameron, I. R., & Bateman, N. T. (1992). Portable liquid oxygen and exercise ability in severe respiratory disability. Thorax. https://doi.org/10.1136/thx.47.10.781
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.