Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 220

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Relation of lung function, maximal inspiratory pressure, dyspnoea, and quality of life with exercise capacity in patients with chronic obstructive pulmonary disease.

Open access
Wijkstra, P J, TenVergert, E M, van der Mark, T W, Postma, D S, Van Altena, R, Kraan, J, Koeter, G H · 1994 · Thorax

Abstract

BACKGROUND: Several studies have shown that both objective and subjective measurements are related to exercise capacity in patients with chronic obstructive pulmonary disease (COPD). In this study the relative contribution of lung function, maximal inspiratory pressure, dyspnoea, and quality of life to the performance in a walking distance test and a bicycle ergometer test was investigated. METHODS: Static lung volumes, forced expiratory volume in one second (FEV1), inspiratory slow vital capacity (IVC), transfer factor for carbon monoxide (TLCO) divided by the alveolar volume (TLCO/VA), static compliance (Cst), and maximal inspiratory peak pressure (PImaxPOES) were measured in 40 patients with COPD with severe airways obstruction (mean FEV1 44% predicted, mean FEV1/IVC 37% predicted). Quality of life was assessed by the Chronic Respiratory Questionnaire (CRQ) and dyspnoea by the Borg category scale. Exercise capacity was measured by both a six minute walking distance (test) and a maximal work load of the bicycle ergometer test (Wmax). RESULTS: Spirometric values and maximal inspiratory pressure were modestly correlated with both the six minute walking test and Wmax, r values ranging from 0.50 to 0.58. The TLCO was strongly correlated with the six minute walking test (r = 0.62) and with Wmax (r = 0.78). Quality of life showed no correlation with exercise capacity, while there was a correlation between dyspnoea and the six minute walking test (r = -0.41). Backward linear regression analysis selected TLCO and PImaxPOES as the most significant determinants for exercise performance. They explained 54% and 69% of the variance in the six minute walking test and Wmax, respectively. CONCLUSIONS: The results show that exercise capacity in patients with COPD with severe airways obstruction is more strongly related to inspiratory muscle strength and lung function than to dyspnoea and quality of life. The significant correlation between dyspnoea and the six minute walking test suggests that subjective variables are more strongly related to walking tests than to bicycle ergometer tests.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.49.5.468

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 220

Metadata

Authors
Wijkstra, P. J., TenVergert, E. M., van der Mark, T. W., Postma, D. S., Van Altena, R., Kraan, J., & Koeter, G. H.
Venue
Thorax
Publisher
BMJ
Published
1994-05-01
Volume
49
Issue
5
Pages
468-472
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2148534399
Cited by
220
References
2
FWCI
10.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.