Adequacy of prescribing nasal continuous positive airway pressure therapy for the sleep apnoea/hypopnoea syndrome on the basis of night time respiratory recording variables.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The increased demand of full polysomnographic studies, not only for diagnostic purposes but also for continuous positive airway pressure (CPAP) titration, has produced long waiting lists. Simpler methods are therefore needed to avoid having to refer all patients for full polysomnography. The hypothesis that CPAP therapy for the sleep apnoea/hypopnoea syndrome (SAHS) can be performed exclusively on the basis of recording night time respiratory variables was tested. METHODS: The level of CPAP in a group of 41 patients (three women) of mean (SD) age 52 (10) years, body mass index 31.5 (4.4) kg/m2, and apnoea/hypopnoea index (AHI) 53(16) events/hour was measured. During a two week period CPAP titration was performed in a random order in two settings: (1) in the sleep laboratory using full polysomnography; and (2) in the respiratory ward using equipment which continuously recorded and displayed pulse oximetry, airflow, chest and abdominal motion, and body position. The level of CPAP was increased progressively until apnoea, hypopnoea, snoring, and thoraco-abdominal paradox disappeared. RESULTS: No differences in CPAP levels (9.34(2.2) versus 9.68 (2.1) cm H2O) were found between full polysomnography and night time respiratory recordings. The accuracy of the measurement of both procedures showed good agreement. Only one patient showed a significant difference in CPAP level requirements between the two methods. CONCLUSIONS: Night time respiratory recording is sufficient to permit a reasonable choice of CPAP levels to abolish all the respiratory disturbances in most of the patients studied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
Evaluation of Positive Airway Pressure Treatment for Sleep Related Breathing Disorders in Adults
Gay, P., Weaver, T., Loube, D., & Iber, C. (2006) · Sleep · doi:10.1093/sleep/29.3.381 · Cited by 614
Bureau, M. P. (2000) · Thorax · doi:10.1136/thorax.55.9.741 · Cited by 23
Pataka, A., Kalamaras, G., Vlachogianni, E., & Argyropoulou, P. (2019) · Pulmonology · doi:10.1016/j.pulmoe.2018.10.004 · Cited by 12
“S-B is a quick and simple screening questionnaire for assessing the risk for OSA.8 It consists of 8 items/questions: snoring, tiredness during daytime, observed apneas, high blood pressure, BMI >35 kg/m2, age (>50 years old), neck circumference (>40 cm) and gender (male).”
Influential
Metadata
- Authors
- Montserrat, J. M., Alarcon, A., Lloberes, P., Ballester, E., Fornas, C., & Rodriguez-Roisin, R.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 1995-09-01
- Volume
- 50
- Issue
- 9
- Pages
- 969-971
- ISSN
- 0040-6376 (ISSN-L)
- OpenAlex
- W2086548777
- Cited by
- 20
- References
- 1
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.