CoChat

Oral appliances for the management of snoring and obstructive sleep apnoea

Open access
Bennett, L. S., Davies, R. J., Stradling, J. R. · 1998 · Thorax
Cited by 58

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Although oral appliances are effective in some patients with obstructive sleep apnoea (OSA), they are not universally effective. A novel anterior mandibular positioner (AMP) has been developed with an adjustable hinge that allows progressive advancement of the mandible. The objective of this prospective crossover study was to compare efficacy, side effects, patient compliance, and preference between AMP and nasal continuous positive airway pressure (nCPAP) in patients with symptomatic mild to moderate OSA. METHODS: Twenty four patients of mean (SD) age 44.0 (10.6) years were recruited with a mean (SD) body mass index of 32.0 (8.2) kg/m2, Epworth sleepiness score 10.7 (3.4), and apnoea/hypopnoea index 26.8 (11.9)/hour. There was a two week wash-in and a two week wash-out period and two treatment periods (AMP and nCPAP) each of four months. Efficacy, side effects, compliance, and preference were evaluated by a questionnaire and home sleep monitoring. RESULTS: One patient dropped out early in the study and three refused to cross over so treatment results are presented on the remaining 20 patients. The apnoea/hypopnoea index (AHI) was lower with nasal CPAP 4.2 (2.2)/hour than with the AMP 13.6 (14.5)/hour (p < 0.01). Eleven of the 20 patients (55%) who used the AMP were treatment successes (reduction of AHI to < 10/hour and relief of symptoms), one (5%) was a compliance failure (unable or unwilling to use the treatment), and eight (40%) were treatment failures (failure to reduce AHI to < 10/hour and/or failure to relieve symptoms). Fourteen of the 20 patients (70%) who used nCPAP were treatment successes, six (30%) were compliance failures, and there were no treatment failures. There was greater patient satisfaction with the AMP (p < 0.01) than with nCPAP but no difference in reported side effects or compliance. CONCLUSIONS: AMP is an effective treatment in some patients with mild to moderate OSA and is associated with greater patient satisfaction than nCPAP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.53.2008.s58

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 58

Metadata

Authors
Bennett, L. S., Davies, R. J., & Stradling, J. R.
Venue
Thorax
Publisher
BMJ
Published
1998-08-01
Volume
53
Issue
Supplement 2
Pages
S58-S64
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2135819242
Cited by
58
References
5
FWCI
2.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Oral appliances for the management of snoring and obstructive sleep apnoea. https://app.cochat.ai/papers/10.1136/thx.53.2008.s58
The paper
Bennett, L. S., Davies, R. J., & Stradling, J. R. (1998). Oral appliances for the management of snoring and obstructive sleep apnoea. Thorax. https://doi.org/10.1136/thx.53.2008.s58

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.