CoChat

Nitrite levels in breath condensate of patients with cystic fibrosis is elevated in contrast to exhaled nitric oxide

Open access
Ho, L P, Innes, J A, Greening, A P · 1998 · Thorax
Cited by 156

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Nitric oxide (NO) is released by activated macrophages, neutrophils, and stimulated bronchial epithelial cells. Exhaled NO has been shown to be increased in patients with asthma and has been put forward as a marker of airways inflammation. However, we have found that exhaled NO is not raised in patients with cystic fibrosis, even during infective pulmonary exacerbation. One reason for this may be that excess airway secretions may prevent diffusion of gaseous NO into the airway lumen. We hypothesised that exhaled NO may not reflect total NO production in chronically suppurative airways and investigated nitrite as another marker of NO production. METHODS: Breath condensate nitrite concentration and exhaled NO levels were measured in 21 clinically stable patients with cystic fibrosis of mean age 26 years and mean FEV1 57% and 12 healthy normal volunteers of mean age 31 years. Breath condensate was collected with a validated method which excluded saliva and nasal air contamination and nitrite levels were measured using the Griess reaction. Exhaled NO was measured using a sensitive chemiluminescence analyser (LR2000) at an exhalation rate of 250 ml/s. Fourteen patients with cystic fibrosis had circulating plasma leucocyte levels and differential analysis performed on the day of breath collection. RESULTS: Nitrite levels were significantly higher in patients with cystic fibrosis than in normal subjects (median 1.93 microM compared with 0.33 microM). This correlated positively with circulating plasma leucocytes and neutrophils (r = 0.6). In contrast, exhaled NO values were not significantly different from the normal range (median 3.8 ppb vs 4.4 ppb). There was no correlation between breath condensate nitrite and lung function and between breath condensate nitrite and exhaled NO. CONCLUSIONS: Nitrite levels in breath condensate were raised in stable patients with cystic fibrosis in contrast to exhaled NO. This suggests that nitrite levels may be a more useful measure of NO production and possibly airways inflammation in suppurative airways and that exhaled NO may not reflect total NO production.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.53.8.680

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Ho, L. P., Innes, J. A., & Greening, A. P.
Venue
Thorax
Publisher
BMJ
Published
1998-08-01
Volume
53
Issue
8
Pages
680-684
ISSN
0040-6376 (ISSN-L)
OpenAlex
W2166466675
Cited by
156
References
4
FWCI
11.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.