CoChat

Nasal pressure recording in the diagnosis of sleep apnoea hypopnoea syndrome

Open access
Series, F, Marc, I · 1999 · Thorax
Cited by 101

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Nasal pressure tracing is now being used to measure breathing in ambulatory screening devices for sleep apnoea but it has not been compared with other methods of assessment. METHODS: Sleep induced breathing disorders were scored by three different methods of analysis (thermistry, inductive plethysmography, and nasal pressure tracing) in 193 consecutive patients referred to our sleep laboratory. With the conventional thermistry method an apnoea was defined as the absence of oronasal flow on the thermistor signal for >/=10 s and a hypopnoea as a 50% decrease in the sum signal of inductive plethysmography tracing for >/=10 s associated with an arousal and/or a 2% decrease in SaO2. Nasal pressure was measured via nasal prongs connected to a pressure transducer. Using the thermistor signal alone, a hypopnoea was defined as a 50% decrease in the signal for >/=10 s associated with an arousal and/or a 2% decrease in SaO2. A similar definition of apnoea and hypopnoea was used for nasal pressure, the fall in pressure being substituted for the thermistor reading. RESULTS: Impaired nasal ventilation prevented adequate measurements of nasal pressure in 9% of subjects. According to the conventional method of interpretation 107 subjects were identified as having the sleep apnoea hypopnoea syndrome (SAHS). The apnoea + hypopnoea index (AHI) was significantly lower using the thermistry method than with conventional analysis (mean difference -4.3/h, 95% CI -5.3 to -3.2, p<10(-4)); 39% of conventional hypopnoeic events were scored as apnoeas using nasal pressure scoring. Apnoeic and hypopnoeic events could also be observed without any change in thermistor and sum Respitrace signals that resumed with the occurrence of arousals or awakenings. The AHI was significantly higher with nasal pressure scoring than with the conventional method (mean difference 4.5, 95% CI 3.4 to 5.6, p<10(-4)). The mean difference in apnoea index between conventional and nasal pressure scoring was -7.5/h (95% CI -8.9 to -6.1). In the 78 patients who did not have SAHS according to the conventional method of analysis there was a significant positive relationship between the arousal index and AHI measured by nasal pressure tracing (R = 0.51, p<10(-4)). Seventeen of the 78 patients had an AHI of >15/h by the nasal pressure method of analysis. CONCLUSIONS: Nasal pressure recording provides a simple and reliable measurement of nocturnal breathing abnormalities and may identify breathing abnormalities associated with arousals that are missed by other diagnostic methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thx.54.6.506

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 101

Metadata

Authors
Series, F., & Marc, I.
Venue
Thorax
Publisher
BMJ
Published
1999-06-01
Volume
54
Issue
6
Pages
506-510
ISSN
0040-6376 (ISSN-L)
OpenAlex
W1976826052
Cited by
101
References
1
FWCI
4.15
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.