Higher Order Positive Semidefinite Diffusion Tensor Imaging
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Due to the well-known limitations of diffusion tensor imaging, high angular resolution diffusion imaging (HARDI) is used to characterize non-Gaussian diffusion processes. One approach to analyzing HARDI data is to model the apparent diffusion coefficient (ADC) with higher order diffusion tensors. The diffusivity function is positive semidefinite. In the literature, some methods have been proposed to preserve positive semidefiniteness of second order and fourth order diffusion tensors. None of them can work for arbitrarily high order diffusion tensors. In this paper, we propose a comprehensive model to approximate the ADC profile by a positive semidefinite diffusion tensor of either second or higher order. We call this the positive semidefinite diffusion tensor (PSDT) model. PSDT is a convex optimization problem with a convex quadratic objective function constrained by the nonnegativity requirement on the smallest Z-eigenvalue of the diffusivity function. The smallest Z-eigenvalue is a computable measure of the extent of positive definiteness of the diffusivity function. We also propose some other invariants for the ADC profile analysis. Experiment results show that higher order tensors could improve the estimation of anisotropic diffusion and that the PSDT model can depict the characterization of diffusion anisotropy which is consistent with known neuroanatomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 1×
“The diffusion tensor imaging (DTI) model was proposed in 1994 by Basser, Mattiello, and LeBihan [6, 7], and is now widely used in biological and clinical research [5].”
MethodEstimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650 · cited 1×
“The diffusion tensor imaging (DTI) model was proposed in 1994 by Basser, Mattiello, and LeBihan [6, 7], and is now widely used in biological and clinical research [5].”
MethodConvex Analysis and Minimization Algorithms I
Hiriart-Urruty, J.-B., & Lemaréchal, C. (1993) · Grundlehren der mathematischen Wissenschaften · doi:10.1007/978-3-662-02796-7 · Cited by 2,378
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
(2005) · Graduate Texts in Mathematics · doi:10.1007/b138611 · Cited by 1,621
A Riemannian Framework for Tensor Computing
Pennec, X., Fillard, P., & Ayache, N. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-005-3222-z · Cited by 1,550 · cited 1×
“In [15], by mapping a fourth order three-dimensional tensor to a second order six-dimensional tensor which is a 6 × 6 matrix, the authors extended the Riemannian framework from second order tensors [2, 20, 25] to the space of fourth order tensors.”
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548 · cited 1×
“[34].”
Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical review
Basser, P. J., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.783 · Cited by 1,478
Eigenvalues of a real supersymmetric tensor
Qi, L. (2005) · Journal of Symbolic Computation · doi:10.1016/j.jsc.2005.05.007 · Cited by 1,440 · cited 14×
“After finding the global minimizer d∗ of PSDT, we may use the method in the appendix to calculate λmin = λmin(d ∗) and the other Z-eigenvalues of d∗ as λ1 ≥ λ2 ≥ · · · ≥ λν ≥ 0.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Qi, L., Yu, G., & Wu, E. X.
- Venue
- SIAM Journal on Imaging Sciences
- Published
- 2010-01
- Volume
- 3
- Issue
- 3
- Pages
- 416-433
- ISSN
- 1936-4954 (ISSN-L)
- OpenAlex
- W2082443028
- Cited by
- 168
- References
- 32
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Higher Order Positive Semidefinite Diffusion Tensor Imaging. https://app.cochat.ai/papers/10.1137/090755138
- The paper
- Qi, L., Yu, G., & Wu, E. X. (2010). Higher Order Positive Semidefinite Diffusion Tensor Imaging. SIAM Journal on Imaging Sciences. https://doi.org/10.1137/090755138
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.