Constrained Total Variation Deblurring Models and Fast Algorithms Based on Alternating Direction Method of Multipliers
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The total variation (TV) model is attractive in that it is able to preserve sharp attributes in images. However, the restored images from TV-based methods do not usually stay in a given dynamic range, and hence projection is required to bring them back into the dynamic range for visual presentation or for storage in digital media. This will affect the accuracy of the restoration as the projected image will no longer be the minimizer of the given TV model. In this paper, we show that one can get much more accurate solutions by imposing box constraints on the TV models and solving the resulting constrained models. Our numerical results show that for some images where there are many pixels with values lying on the boundary of the dynamic range, the gain can be as great as 10.28 decibel in the peak signal-to-noise ratio. One traditional hindrance using the constrained model is that it is difficult to solve. However, in this paper, we propose using the alternating direction method of multipliers (ADMM) to solve the constrained models. This leads to a fast and convergent algorithm that is applicable for both Gaussian and impulse noise. Numerical results show that our ADMM algorithm is better than some state-of-the-art algorithms for unconstrained models in terms of both accuracy and robustness with respect to the regularization parameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
A Fast Iterative Shrinkage-Thresholding Algorithm for Linear Inverse Problems
Beck, A., & Teboulle, M. (2009) · SIAM Journal on Imaging Sciences · doi:10.1137/080716542 · Cited by 11,952 · cited 3×
“In fact, the authors have shown in [3] that the convergence rate of FISTA is O ( k − 2 ).”
A New TwIST: Two-Step Iterative Shrinkage/Thresholding Algorithms for Image Restoration
Bioucas-Dias, J. M., & Figueiredo, M. A. T. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.909319 · Cited by 2,064 · cited 1×
“There are many efforts to improve its speed, such as, the two-step IST (TwIST) algorithm [5], and the fast IST algorithm (FISTA) [3].”
MethodA New Alternating Minimization Algorithm for Total Variation Image Reconstruction
Wang, Y., Yang, J., Yin, W., & Zhang, Y. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/080724265 · Cited by 1,975 · cited 10×
“We compare our algorithms with the state-of-the-art solvers, like FTVd [39] and the augmented Lagrange method (ALM) [41] for the unconstrained model (1.1); and MFISTA [4] for the constrained model (1.2).”
BackgroundMethodInfluential
Metadata
- Authors
- Chan, R. H., Tao, M., & Yuan, X.
- Venue
- SIAM Journal on Imaging Sciences
- Published
- 2013-01
- Volume
- 6
- Issue
- 1
- Pages
- 680-697
- ISSN
- 1936-4954 (ISSN-L)
- OpenAlex
- W2087670913
- Cited by
- 208
- References
- 4
- FWCI
- 20.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.