Application of Near Infrared Spectroscopy to Exercise Sports Science
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Over the past 15 years the use of near infrared spectroscopy in exercise and sports science has increased exponentially. The majority of these studies have used this noninvasive technique to provide information related to tissue metabolism during acute exercise. This has been undertaken to determine its utility as a suitable tool to provide new insights into the heterogeneity and regulation of local tissue metabolism, both in cerebral and skeletal muscle tissue. In the accompanying articles in this symposium, issues related to the principles, techniques, limitations (Ferrari et al., 2004), and reliability and validity of NIRS in both cerebral and skeletal muscle tissue (Bhambhani, 2004), mostly during acute exercise, have been addressed and will not be discussed here. Instead, the present paper will focus specifically on the application of NIRS to exercise sports science, with an emphasis on how this technology has been applied to exercise training and sport, and how it can be used to design training programs for athletes. Key words: tissue de-oxygenation, hemoglobin volume, endurance training, resistance exercise, taper, applied physiology
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Blood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248 · cited 2×
“Thus, the discrepancy between the NIRS and femoral results reported by both MacDonald et al. (1999) and Hicks et al. (1999) is likely related to the area of sampling of the NIRS probe (localized to the small vessels) vs. the regional venous return from the entire leg musculature (obtained from…”
BackgroundResultBelardinelli, R., Barstow, T. J., Porszasz, J., & Wasserman, K. (1995) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00634377 · Cited by 213 · cited 2×
“This trend was identical to that observed by others during incremental maximal exercise (Belardinelli et al., 1995; Bhambhani et al., 1997; Costes et al., 1996). However, during the simulated 20TT race, muscle oxygenation rapidly decreased at the onset of exercise (0–2 km) and continued to decline gradually until the…”
ResultMuscle ultrastructural characteristics of elite powerlifters and bodybuilders
MacDougall, J. D., Sale, D. G., Elder, G. C. B., & Sutton, J. R. (1982) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421171 · Cited by 205
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149 · cited 5×
“Passons, parce qu’elle a été discutée précédemment, la question des principes, des techniques, des limites, de la fiabilité, et de la validité de la NIRS pour l’étude des tissus cérébral et musculaire (Bhambhani 2004), surtout au cours d’un effort donné.”
BackgroundInfluentialCostes, F., Barthelemy, J. C., Feasson, L., Busso, T., Geyssant, A., & Denis, C. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1345 · Cited by 101 · cited 4×
“This finding differs from that of Costes et al. (2001) as cited above. However, there is no physiological reason why there would be a difference in the oxygen cost at a given power output regardless of whether it was before or after a period of training. Thus, it is likely that the difference between these two studies…”
ResultInfluentialComparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
MacDonald, M. J., Tarnopolsky, M. A., Green, H. J., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.687 · Cited by 98 · cited 2×
“Thus, the discrepancy between the NIRS and femoral results reported by both MacDonald et al. (1999) and Hicks et al. (1999) is likely related to the area of sampling of the NIRS probe (localized to the small vessels) vs. the regional venous return from the entire leg musculature (obtained from…”
BackgroundResultDetection of ventilatory threshold using near infrared spectroscopy in men and women
BHAMBHANI, Y. N., BUCKLEY, S. M., & SUSAKI, T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199703000-00017 · Cited by 89 · cited 1×
“This trend was identical to that observed by others during incremental maximal exercise (Belardinelli et al., 1995; Bhambhani et al., 1997; Costes et al., 1996).”
ResultEffect of cycling experience and pedal cadence on the near-infrared spectroscopy parameters
TAKAISHI, T., ISHIDA, K., KATAYAMA, K., YAMAZAKI, K., YAMAMOTO, T., & MORITANI, T. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200212000-00030 · Cited by 38
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
“Later Neary [11] focused his review article on the application of NIRS to exercise sports science, with an emphasis on how it can be used to design training programs for athletes.”
BackgroundEkkekakis, P. (2009) · Journal of Sport and Exercise Psychology · doi:10.1123/jsep.31.4.505 · Cited by 218
“NIRS-Based Investigations of Cortical Hemodynamics in Exercise Research NIRS technology has been used in exercise science for several years but has been applied mainly to the noninvasive investigation of the hemodynamics of the working muscle (e.g., Bhambhani, 2004; Boushel et al., 2001; Neary, 2004; Pereira, Gomes, &…”
Method
Metadata
- Authors
- Neary, J. P.
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 2004-08-01
- Volume
- 29
- Issue
- 4
- Pages
- 488-503
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2119726594
- Cited by
- 73
- References
- 11
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.