Validity and Reliability of the Cosmed K2 to Measure Oxygen Uptake
The DOI matches its Crossref record.
Abstract
The validity and reliability of the Cosmed K2 was tested in comparison with a Quinton on-line oxygen analysing system. A female subject was monitored on a treadmill using a progressive protocol and was measured on three occasions with each system. It was found at low workloads that the Cosmed K2 and the Quinton gave the same measure of oxygen uptake; at higher workloads the Cosmed K2 gave lower values, and at peak oxygen uptake the Cosmed K2 measured 22.2% less than the Quinton. The difference in the measurement of [Formula: see text] at peak oxygen uptake was 13%. The Cosmed K2's measurement of [Formula: see text] showed a greater variability between trials (variation coefficient 3.0-11.4%) than the Quinton (variation coefficient 1.1-3.9%). Key words: Cosmed K2, validity, telemetry
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240
“Lothian et al. (1993) 1 Incremental TM Cosmed K2 VO 2 , 3.0–14.0 Lucia et al. (1993) 20 Sub-maximal and maximal TM tests Cosmed K2 VO 2 , 0.01 (NR)”
BackgroundInfluentialAutomated Metabolic Gas Analysis Systems: A Review
Macfarlane, D. J. (2001) · Sports Medicine · doi:10.2165/00007256-200131120-00002 · Cited by 198
Evaluation of the Oxycon Mobile metabolic system against the Douglas bag method
Rosdahl, H., Gullstrand, L., Salier-Eriksson, J., Johansson, P., & Schantz, P. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1326-9 · Cited by 181
“One early study, including a single subject running on a treadmill at different speeds, reported a _ VO2 CV of 3–11% for the first version of the Cosmed K2 portable breath-by-breath system (Lothian et al. 1993), while in a more recent study a CV of 14% was reported for the VO2000 system (Crouter et al.”
MethodEnergy cost of sport rock climbing in elite performers
Booth, J., Marino, F., Hill, C., & Gwinn, T. (1999) · British Journal of Sports Medicine · doi:10.1136/bjsm.33.1.14 · Cited by 93
Pinnington, H. C., Wong, P., Tay, J., Green, D., & Dawson, B. (2001) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(01)80041-4 · Cited by 77
Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
(2020) · International Journal of Exercise Science · doi:10.70252/thjt1177 · Cited by 39
“Past work with the COSMED K2 and K4b2 found coefficients of variation of ~3-13% for VO2 and minute ventilation variables during submaximal and maximal exercise (13, 14, 29), and these are slightly better than the 11.”
MethodLITTLEWOOD, R. (2002) · Clinical Nutrition · doi:10.1054/clnu.2002.0580 · Cited by 30
Metadata
- Authors
- Lothian, F., Farrally, M. R., & Mahoney, C.
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 1993-06-01
- Volume
- 18
- Issue
- 2
- Pages
- 197-206
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2150262111
- Cited by
- 36
- References
- 0
- FWCI
- 7.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.