Variability of Time to Exhaustion During Submaximal Exercise
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Exercise time to exhaustion (TE) is commonly used to evaluate the success or failure of such treatments as endurance training programs or nutritional supplements. The present study determined the variability of TE during submaximal exercise at 80% [Formula: see text]. Fifteen males performed cycle exercise to exhaustion on five occasions at the same time of day with a minimum of 72 hrs between sessions. There was no difference in TE (0.1 > p > 0.05) among the trials, with values ranging from 14.4 ± 1.1 min for Test 1 to 18.2 ± 2.4 min during the final test. Substantial variability in TE over the five trials was observed among subjects with coefficients of variation (CV) ranging from 2.8 to 31.4%. Subjects were divided into two groups using the median CV for TE. For the low CV group (n = 8), TE was significantly increased during Test 3 (14.9 ± 1.3 min) compared with Test 1 (12.8 ± 1.0 min) and Test 5 (12.5 ± 1.2 min). For the high CV group (n = 7), TE was increased during Test 5 (24.7 ± 3.7 min) compared with the other tests (18.5 ± 2.2 min). CV for [Formula: see text], [Formula: see text], pH, [Formula: see text], and rectal temperature were less than 5% and did not differ between groups. Post hoc power calculations revealed that if all subjects were considered as one group, sample size would have to increase to 40 to increase the power to 0.8. Due to the variability in TE that may be observed with males of average fitness, it is concluded that TE should not be the only dependent measure used to evaluate treatment effects during submaximal exercise. Key words: coefficient of variation, blood lactate, sample size, power
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reversal of fatigue during prolonged exercise by carbohydrate infusion or ingestion
Coggan, A. R., & Coyle, E. F. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.63.6.2388 · Cited by 392
Potential for strength and endurance training to amplify endurance performance
Hickson, R. C., Dvorak, B. A., Gorostiaga, E. M., Kurowski, T. T., & Foster, C. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.5.2285 · Cited by 295
Cited by
Reliability of Power in Physical Performance Tests
Hopkins, W. G., Schabort, E. J., & Hawley, J. A. (2001) · Sports Medicine · doi:10.2165/00007256-200131030-00005 · Cited by 825
Validity, Reliability and Sensitivity of Measures of Sporting Performance
Currell, K., & Jeukendrup, A. E. (2008) · Sports Medicine · doi:10.2165/00007256-200838040-00003 · Cited by 768
Bishop, D. (2003) · Sports Medicine · doi:10.2165/00007256-200333060-00005 · Cited by 715
Effects of the Menstrual Cycle on Exercise Performance
Janse de Jonge, X. A. K. (2003) · Sports Medicine · doi:10.2165/00007256-200333110-00004 · Cited by 432
Significance of the Velocity at &OV0312;O2max and Time to Exhaustion at this Velocity
Billat, L. V., & Koralsztein, J. P. (1996) · Sports Medicine · doi:10.2165/00007256-199622020-00004 · Cited by 380
Metadata
- Authors
- McLellan, T. M., Cheung, S. S., & Jacobs, I.
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 1995-03-01
- Volume
- 20
- Issue
- 1
- Pages
- 39-51
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2164014823
- Cited by
- 117
- References
- 2
- FWCI
- 15.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.