The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
INTERACTION OF SLOW ELECTRONS WITH CHEMISORBED OXYGEN
Abstract
Measurements have been made of the effects of low-energy electron bombardment (0–300 ev) on a chemisorbed layer of oxygen on polycrystalline molybdenum. Oxygen is adsorbed in two states at room temperature with approximate heats of adsorption of 60 and 110 kcal/mole, respectively. O+ ions are released from the weakly bound state with a maximum probability of 10−5 ion/electron at an electron energy of 90 ev. The ion-energy distribution, measured by a retarding-field method, has a maximum at about 6 ev and a half-width of 5 ev. About 50 neutrals are released for every ion. The measured threshold energy, 17.6 ± 0.2 ev, for ion formation is in good agreement with the calculated value. The probability of ion and neutral release from the strongly bonded state is about 2 × 10 3 times smaller than for the weakly bonded state. A qualitative explanation of the formation of neutrals is proposed in terms of Auger neutralization of the ions near the surface. Reflection of the ion-energy distribution in the calculated curve of the potential energy of the O+ ion yields, after correction for Auger neutralization, the probability density distribution of the adsorbed oxygen atom. The equilibrium spacing of the chemisorbed atom is then estimated to be 1.67 Å.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effects of adsorbed oxygen on measurements with ionization gauges
Redhead, P. A. (1963) · Vacuum · doi:10.1016/0042-207x(63)90859-5 · Cited by 92
Self-citationQuantum Limits of the Electrostatic Image Force Theory
Sachs, R. G., & Dexter, D. L. (1950) · Journal of Applied Physics · doi:10.1063/1.1699595 · Cited by 80
Cited by
Ion Desorption by Core-Hole Auger Decay
Knotek, M. L., & Feibelman, P. J. (1978) · Physical Review Letters · doi:10.1103/physrevlett.40.964 · Cited by 1,116
Gas-assisted focused electron beam and ion beam processing and fabrication
Utke, I., Hoffmann, P., & Melngailis, J. (2008) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.2955728 · Cited by 1,026
Desorption from Metal Surfaces by Low-Energy Electrons
Menzel, D., & Gomer, R. (1964) · The Journal of Chemical Physics · doi:10.1063/1.1725730 · Cited by 996
Femtosecond time-resolved two-photon photoemission studies of electron dynamics in metals
Petek, H., & Ogawa, S. (1997) · Progress in Surface Science · doi:10.1016/s0079-6816(98)00002-1 · Cited by 730
Photochemistry at adsorbate/metal interfaces
Zhou, X.-L., Zhu, X.-Y., & White, J. M. (1991) · Surface Science Reports · doi:10.1016/0167-5729(91)90009-m · Cited by 514
Metadata
- Authors
- Redhead, P. A.
- Venue
- Canadian Journal of Physics
- Publisher
- Canadian Science Publishing
- Published
- 1964-05-01
- Volume
- 42
- Issue
- 5
- Pages
- 886-905
- ISSN
- 0008-4204 (ISSN-L)
- 1208-6045
- OpenAlex
- W2053290544
- Cited by
- 907
- References
- 2
- FWCI
- 6.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.